Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1993
Principal Product Dimensional Lumber
NAICS n/a
SIC 2421 - Sawmills And Planing Mills, General
Sales $10,000,000-$50,000,000
# of Employees 117
Plant Area (Sq.Ft.) 0
Annual Production 101,000 Thousand Feet
Production Hrs. Annual 8,736
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $400,306 10,441,970 kWh $0.04
Wood $186,380 111,828 MMBtu $1.67
TOTAL ENERGY COSTS $586,686
RECOMMENDED SAVINGS* $45,340 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $39,340
#|Description Savings
Cost
Status Electricity Usage Other Energy Electricity Usage Other Energy
$ kWh $ MMBtu
01: 2.1232 KEEP BOILER TUBES CLEAN Savings:
$26,620
Cost:
$4,000
- - $26,620 1,331 -
-
kWh
$26,620
1,331
MMBtu
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$6,000
Cost:
$1,700
- - $6,000 300 -
-
kWh
$6,000
300
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,496
Cost:
$3,000
$2,496 67,702 - - $2,496
67,702
kWh
-
-
MMBtu
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,115
Cost:
$2,857
$1,115 29,308 - - $1,115
29,308
kWh
-
-
MMBtu
05: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$2,478
Cost:
$7,050
$2,478 - - - $2,478
-
kWh
-
-
MMBtu
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$6,631
Cost:
$30,340
$6,631 202,227 - - $6,631
202,227
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$45,340
Cost:
$48,947
$12,720 299,237 $32,620 1,631 $12,720
299,237
kWh
$32,620
1,631
MMBtu
TOTAL IMPLEMENTED Savings:
$39,340
Cost:
$47,247
$12,720 299,237 $26,620 1,331 $12,720
299,237
kWh
$26,620
1,331
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Other Energy Electricity Usage Other Energy