Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 1996 |
Principal Product | powdered milk |
NAICS | n/a |
SIC | 2023 - Dry, Condensed, Evaporated Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 80,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $384,440 | 15,506,155 | kWh | $0.02 |
Electricity Demand | $152,410 | 31,752 | kW-months/year | $4.80 |
Electricity Fees | $9,062 | - | $ | - |
Natural Gas | $760,986 | 210,807 | MMBtu | $3.61 |
TOTAL ENERGY COSTS | $1,317,718 | |||
RECOMMENDED SAVINGS* | $69,710 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $59,150 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1232 KEEP BOILER TUBES CLEAN |
Savings: $10,640 Cost: $800 |
- | - | - | - | $11,120 | 3,080 | - | - | $(-480) | - |
- - kWh |
- - kW-months/year |
$11,120 3,080 MMBtu |
- - lb |
$(-480) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $18,000 Cost: $128,480 |
$18,000 | 726,260 | - | - | - | - | - | - | - | - |
$18,000 726,260 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $16,450 Cost: $34,810 |
$11,920 | 480,657 | $4,530 | 943 | - | - | - | - | - | - |
$11,920 480,657 kWh |
$4,530 943 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,510 Cost: $11,180 |
$2,620 | 105,803 | $890 | 185 | - | - | - | - | - | - |
$2,620 105,803 kWh |
$890 185 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $7,790 Cost: $2,000 |
$7,790 | 314,478 | - | - | - | - | - | - | - | - |
$7,790 314,478 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $2,770 Cost: $5,000 |
$2,770 | 111,958 | - | - | - | - | - | - | - | - |
$2,770 111,958 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $10,430 Cost: $50,000 |
$9,805 | 395,662 | $625 | 193 | - | - | - | - | - | - |
$9,805 395,662 kWh |
$625 193 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $120 Cost: - |
- | - | - | - | - | - | $120 | 2,600 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$120 2,600 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $69,710 Cost: $232,270 |
$52,905 | 2,134,818 | $6,045 | 1,321 | $11,120 | 3,080 | $120 | 2,600 | $(-480) | - | $52,905 2,134,818 kWh |
$6,045 1,321 kW-months/year |
$11,120 3,080 MMBtu |
$120 2,600 lb |
$(-480) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $59,150 Cost: $225,270 |
$42,345 | 1,708,382 | $6,045 | 1,321 | $11,120 | 3,080 | $120 | 2,600 | $(-480) | - | $42,345 1,708,382 kWh |
$6,045 1,321 kW-months/year |
$11,120 3,080 MMBtu |
$120 2,600 lb |
$(-480) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |