Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2000 |
Principal Product | Specialized Lumber |
NAICS | n/a |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $1,000,000-$5,000,000 |
# of Employees | 23 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 4,800 Thousand Feet |
Production Hrs. Annual | 2,210 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $49,578 | 1,199,590 | kWh | $0.04 |
Electricity Demand | $23,588 | 87,216 | kW-months/year | $0.27 |
Electricity Fees | $918 | - | $ | - |
Natural Gas | $29,457 | 7,492 | MMBtu | $3.93 |
TOTAL ENERGY COSTS | $103,541 | |||
RECOMMENDED SAVINGS* | $3,704 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $610 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,963 Cost: $8,640 |
$1,963 | 47,479 | - | - | - | - | - | - | - | - |
$1,963 47,479 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $199 Cost: - |
$100 | 2,345 | $36 | 13 | - | - | $35 | - | $28 | - |
$100 2,345 kWh |
$36 13 kW-months/year |
- - $ |
$35 - $ |
$28 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $200 Cost: $850 |
$200 | 4,982 | - | 12 | - | - | - | - | - | - |
$200 4,982 kWh |
- 12 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $610 Cost: $4,000 |
$490 | 12,016 | $120 | 60 | - | - | - | - | - | - |
$490 12,016 kWh |
$120 60 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $732 Cost: $5,000 |
- | - | - | - | $732 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$732 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $3,704 Cost: $18,490 |
$2,753 | 66,822 | $156 | 85 | $732 | - | $35 | - | $28 | - | $2,753 66,822 kWh |
$156 85 kW-months/year |
$732 - $ |
$35 - $ |
$28 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $610 Cost: $4,000 |
$490 | 12,016 | $120 | 60 | - | - | - | - | - | - | $490 12,016 kWh |
$120 60 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material |