Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2000 |
Principal Product | Softwood Veneer |
NAICS | n/a |
SIC | 2436 - Softwood Veneer And Plywood |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 1,280,000,000 Thousand Feet |
Production Hrs. Annual | 4,680 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $302,762 | 6,799,238 | kWh | $0.04 |
Natural Gas | $315,161 | 77,419 | MMBtu | $4.07 |
TOTAL ENERGY COSTS | $617,923 | |||
RECOMMENDED SAVINGS* | $1,065,886 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,110 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,383 Cost: $7,000 |
$4,286 | 125,440 | $1,097 | 322 | - | - | - | - | - | - |
$4,286 125,440 kWh |
$1,097 322 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $9,673 Cost: $15,010 |
$7,758 | 227,140 | $1,915 | 562 | - | - | - | - | - | - |
$7,758 227,140 kWh |
$1,915 562 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,146 Cost: - |
$900 | 26,377 | $246 | 72 | - | - | - | - | - | - |
$900 26,377 kWh |
$246 72 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $3,099 Cost: $885 |
$2,897 | 84,701 | $202 | 178 | - | - | - | - | - | - |
$2,897 84,701 kWh |
$202 178 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,229 Cost: - |
$1,729 | 50,703 | - | - | - | - | $42 | - | $458 | - |
$1,729 50,703 kWh |
- - kW-months/year |
- - $ |
$42 - $ |
$458 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8112 COMBINE UTILITY METERS |
Savings: $1,715 Cost: $4,000 |
- | - | $494 | - | $1,221 | - | - | - | - | - |
- - kWh |
$494 - kW-months/year |
$1,221 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS |
Savings: $9,628 Cost: $48,484 |
$7,525 | 220,397 | $2,103 | 617 | - | - | - | - | - | - |
$7,525 220,397 kWh |
$2,103 617 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $7,013 Cost: $19,600 |
- | - | - | - | $7,013 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,013 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $1,026,000 Cost: $1,337,500 |
- | - | - | - | - | - | - | - | $1,026,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$1,026,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,065,886 Cost: $1,432,479 |
$25,095 | 734,758 | $6,057 | 1,751 | $8,234 | - | $42 | - | $1,026,458 | - | $25,095 734,758 kWh |
$6,057 1,751 kW-months/year |
$8,234 - $ |
$42 - $ |
$1,026,458 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,110 Cost: $56,369 |
$14,708 | 430,538 | $3,402 | 1,117 | - | - | - | - | - | - | $14,708 430,538 kWh |
$3,402 1,117 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Primary Raw Material |