Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2001 |
Principal Product | Lumber |
NAICS | n/a |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 135 |
Plant Area (Sq.Ft.) | 2,178,008 |
Annual Production | 39,910,000 Thousand Feet |
Production Hrs. Annual | 4,160 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $281,876 | 11,412,000 | kWh | $0.02 |
Electricity Demand | $160,506 | 347,040 | kW-months/year | $0.46 |
Electricity Fees | $12,859 | - | $ | - |
TOTAL ENERGY COSTS | $455,241 | |||
RECOMMENDED SAVINGS* | $1,538,074 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $43,074 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $1,495,000 Cost: $2,000,000 |
- | - | - | - | - | - | $190,000 | - | $(-150,000) | - | $1,455,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$190,000 - $ |
$(-150,000) - $ |
$1,455,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $20,011 Cost: $85,079 |
$20,011 | 810,179 | - | - | - | - | - | - | - | - | - | - |
$20,011 810,179 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,184 Cost: $12,000 |
- | - | - | - | $12,184 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,184 - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $10,080 Cost: $37,263 |
$5,678 | 229,880 | $4,402 | 793 | - | - | - | - | - | - | - | - |
$5,678 229,880 kWh |
$4,402 793 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $799 Cost: $800 |
$494 | 20,000 | $305 | 55 | - | - | - | - | - | - | - | - |
$494 20,000 kWh |
$305 55 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,538,074 Cost: $2,135,142 |
$26,183 | 1,060,059 | $4,707 | 848 | $12,184 | - | $190,000 | - | $(-150,000) | - | $1,455,000 | - | $26,183 1,060,059 kWh |
$4,707 848 kW-months/year |
$12,184 - $ |
$190,000 - $ |
$(-150,000) - $ |
$1,455,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $43,074 Cost: $135,142 |
$26,183 | 1,060,059 | $4,707 | 848 | $12,184 | - | - | - | - | - | - | - | $26,183 1,060,059 kWh |
$4,707 848 kW-months/year |
$12,184 - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Increase in Production |