Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2003 |
Principal Product | Door Frame Parts |
NAICS | 321911 - Wood Window and Door Manufacturing |
SIC | 2431 - Millwork |
Sales | $50,000,000-$100,000,000 |
# of Employees | 260 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 27,100,000 Thousand Feet |
Production Hrs. Annual | 0 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $292,292 | 7,745,142 | kWh | $0.04 |
Electricity Demand | $97,026 | 290,352 | kW-months/year | $0.33 |
Electricity Fees | $7,867 | - | $ | - |
Natural Gas | $57,446 | 8,607 | MMBtu | $6.67 |
TOTAL ENERGY COSTS | $454,631 | |||
RECOMMENDED SAVINGS* | $585,730 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $50,680 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $508,000 Cost: $28,000 |
- | - | - | - | - | - | - | - | $508,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$508,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $9,000 Cost: $8,100 |
$9,000 | 246,000 | - | - | - | - | - | - | - | - |
$9,000 246,000 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $21,800 Cost: $21,600 |
$15,200 | 415,000 | $6,600 | 1,656 | - | - | - | - | - | - |
$15,200 415,000 kWh |
$6,600 1,656 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,100 Cost: $13,000 |
$11,500 | 314,000 | $1,600 | 408 | - | - | - | - | - | - |
$11,500 314,000 kWh |
$1,600 408 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $27,050 Cost: $98,000 |
$12,609 | 203,800 | $6,013 | 1,500 | $406 | - | $8,022 | - | - | - |
$12,609 203,800 kWh |
$6,013 1,500 kW-months/year |
$406 - $ |
$8,022 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $6,780 Cost: $26,000 |
$(-2,870) | (-92,500) | - | - | $1,440 | - | $8,210 | - | - | - |
$(-2,870) (-92,500) kWh |
- - kW-months/year |
$1,440 - $ |
$8,210 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $585,730 Cost: $194,700 |
$45,439 | 1,086,300 | $14,213 | 3,564 | $1,846 | - | $16,232 | - | $508,000 | - | $45,439 1,086,300 kWh |
$14,213 3,564 kW-months/year |
$1,846 - $ |
$16,232 - $ |
$508,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $50,680 Cost: $68,700 |
$32,830 | 882,500 | $8,200 | 2,064 | $1,440 | - | $8,210 | - | - | - | $32,830 882,500 kWh |
$8,200 2,064 kW-months/year |
$1,440 - $ |
$8,210 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product |