Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2004
Principal Product Lumber
NAICS 321912 - Cut Stock, Resawing Lumber, and Planing
SIC 2421 - Sawmills And Planing Mills, General
Sales $10,000,000-$50,000,000
# of Employees 115
Plant Area (Sq.Ft.) 200,000
Annual Production 64,990,000 Thousand Feet
Production Hrs. Annual 8,652
Location (State) ID
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $424,660 8,452,880 kWh $0.05
Electricity Demand $73,295 25,822 kW-months/year $2.84
Electricity Fees $7,188 - $ -
TOTAL ENERGY COSTS $505,143
RECOMMENDED SAVINGS* $122,960 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $87,560
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Wood Ancillary Material Cost Electricity Usage Electricity Demand Wood Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,060
Cost:
$3,000
$2,700 54,000 $360 132 - - - - $2,700
54,000
kWh
$360
132
kW-months/year
-
-
MMBtu
-
-
$
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$3,700
Cost:
-
$3,700 73,500 - - - - - - $3,700
73,500
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$26,000
Cost:
$22,920
$26,000 519,000 - - - - - - $26,000
519,000
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$7,000
Cost:
$10,000
$6,000 119,800 $1,000 360 - - - - $6,000
119,800
kWh
$1,000
360
kW-months/year
-
-
MMBtu
-
-
$
05: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION Savings:
$73,800
Cost:
$600
- - - - $73,800 43,600 - - -
-
kWh
-
-
kW-months/year
$73,800
43,600
MMBtu
-
-
$
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$9,400
Cost:
$1,000
$7,400 147,000 - - - - $2,000 - $7,400
147,000
kWh
-
-
kW-months/year
-
-
MMBtu
$2,000
-
$
TOTAL RECOMMENDED Savings:
$122,960
Cost:
$37,520
$45,800 913,300 $1,360 492 $73,800 43,600 $2,000 - $45,800
913,300
kWh
$1,360
492
kW-months/year
$73,800
43,600
MMBtu
$2,000
-
$
TOTAL IMPLEMENTED Savings:
$87,560
Cost:
$13,600
$12,400 247,300 $1,360 492 $73,800 43,600 - - $12,400
247,300
kWh
$1,360
492
kW-months/year
$73,800
43,600
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Wood Ancillary Material Cost Electricity Usage Electricity Demand Wood Ancillary Material Cost