Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2005 |
Principal Product | Wool Textiles |
NAICS | 313210 - Broadwoven Fabric Mills |
SIC | 2231 - Broadwoven Fabric Mills, Wool |
Sales | $10,000,000-$50,000,000 |
# of Employees | 270 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 4,500,000 Thousand Feet |
Production Hrs. Annual | 8,760 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $385,000 | 9,200,000 | kWh | $0.04 |
Electricity Demand | $131,000 | 288,000 | kW-months/year | $0.45 |
Natural Gas | $700,000 | 116,000 | MMBtu | $6.03 |
TOTAL ENERGY COSTS | $1,364,000 | |||
RECOMMENDED SAVINGS* | $334,467 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,367 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4151 MINIMIZE WATER USAGE |
Savings: $215,000 Cost: $620,000 |
- | - | - | - | $148,000 | 230,000 | $24,000 | 30,000,000 | $43,000 | - |
- - kWh |
- - kW-months/year |
$148,000 230,000 MMBtu |
$24,000 30,000,000 Tgal |
$43,000 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4151 MINIMIZE WATER USAGE |
Savings: $51,000 Cost: $107,000 |
- | - | - | - | $51,000 | 81,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$51,000 81,000 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2128 USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) |
Savings: $39,000 Cost: $16,400 |
- | - | - | - | $39,000 | 62,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$39,000 62,000 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $17,600 Cost: $23,000 |
- | - | - | - | $17,600 | 29,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$17,600 29,000 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,630 Cost: - |
$3,500 | 57,730 | $1,130 | 17 | - | - | - | - | - | - |
$3,500 57,730 kWh |
$1,130 17 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,637 Cost: $3,150 |
$3,637 | 82,492 | - | - | - | - | - | - | - | - |
$3,637 82,492 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,100 Cost: $104 |
$2,100 | 49,600 | - | - | - | - | - | - | - | - |
$2,100 49,600 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,500 Cost: $600 |
$1,400 | 34,000 | $100 | 100 | - | - | - | - | - | - |
$1,400 34,000 kWh |
$100 100 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $334,467 Cost: $770,254 |
$10,637 | 223,822 | $1,230 | 117 | $255,600 | 402,000 | $24,000 | 30,000,000 | $43,000 | - | $10,637 223,822 kWh |
$1,230 117 kW-months/year |
$255,600 402,000 MMBtu |
$24,000 30,000,000 Tgal |
$43,000 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,367 Cost: $3,254 |
$9,237 | 189,822 | $1,130 | 17 | - | - | - | - | - | - | $9,237 189,822 kWh |
$1,130 17 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption |