Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2008 |
Principal Product | Doors |
NAICS | 321911 - Wood Window and Door Manufacturing |
SIC | 2431 - Millwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 115 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 8,897 Thousand Feet |
Production Hrs. Annual | 2,080 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,107 | 1,285,242 | kWh | $0.03 |
Electricity Demand | $18,810 | 3,420 | kW-months/year | $5.50 |
Electricity Fees | $2,435 | - | $ | - |
Natural Gas | $63,500 | 6,045 | MMBtu | $10.50 |
TOTAL ENERGY COSTS | $127,852 | |||
RECOMMENDED SAVINGS* | $81,297 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $42,837 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Fees | Other Energy | Primary Product | Electricity Usage | Electricity Fees | Other Energy | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $34,537 Cost: - |
- | - | - | - | - | - | $34,537 | - |
- - kWh |
- - $ |
- - MMBtu |
$34,537 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $19,500 Cost: $157,850 |
$19,500 | 2,000 | - | - | - | - | - | - |
$19,500 2,000 kWh |
- - $ |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $8,560 Cost: $3,680 |
- | - | - | - | $8,560 | - | - | - |
- - kWh |
- - $ |
$8,560 - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,000 Cost: $44,710 |
$7,000 | 244 | - | - | - | - | - | - |
$7,000 244 kWh |
- - $ |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $8,300 Cost: $2,500 |
$8,300 | 631 | - | - | - | - | - | - |
$8,300 631 kWh |
- - $ |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,400 Cost: $5,075 |
- | - | $3,400 | - | - | - | - | - |
- - kWh |
$3,400 - $ |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,297 Cost: $213,815 |
$34,800 | 2,875 | $3,400 | - | $8,560 | - | $34,537 | - | $34,800 2,875 kWh |
$3,400 - $ |
$8,560 - MMBtu |
$34,537 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $42,837 Cost: $2,500 |
$8,300 | 631 | - | - | - | - | $34,537 | - | $8,300 631 kWh |
- - $ |
- - MMBtu |
$34,537 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Fees | Other Energy | Primary Product | Electricity Usage | Electricity Fees | Other Energy | Primary Product |