Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2008 |
Principal Product | High Voltage Cable |
NAICS | 331318 - Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3357 - Nonferrous Wiredrawing & Insulating |
Sales | $100,000,000-$500,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 146,800 Units |
Production Hrs. Annual | 8,760 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $397,579 | 10,233,686 | kWh | $0.04 |
Electricity Demand | $69,786 | 24,064 | kW-months/year | $2.90 |
Electricity Fees | $65,425 | - | $ | - |
Natural Gas | $118,265 | 127,756 | MMBtu | $0.93 |
TOTAL ENERGY COSTS | $651,055 | |||
RECOMMENDED SAVINGS* | $664,990 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $218,543 Cost: $1,128,211 |
$113,514 | 9,964 | $(-9,061) | - | - | - | $114,090 | - | - | - | - | - |
$113,514 9,964 kWh |
$(-9,061) - kW-months/year |
- - $ |
$114,090 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3322 USE EXISTING DAM TO GENERATE ELECTRICITY |
Savings: $31,589 Cost: $50,000 |
- | - | - | - | $31,589 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$31,589 - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,432 Cost: $23,075 |
$2,918 | 75,130 | $98 | 3 | - | - | $645 | - | - | - | $1,771 | - |
$2,918 75,130 kWh |
$98 3 kW-months/year |
- - $ |
$645 - $ |
- - $ |
$1,771 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $106,649 Cost: $758,330 |
$96,766 | 2,490,750 | $9,883 | 8,493 | - | - | - | - | - | - | - | - |
$96,766 2,490,750 kWh |
$9,883 8,493 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $15,317 Cost: $72,600 |
$12,157 | 312,920 | $3,160 | 1,068 | - | - | - | - | - | - | - | - |
$12,157 312,920 kWh |
$3,160 1,068 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $4,450 Cost: $19,950 |
- | - | - | - | $4,450 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,450 - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,860 Cost: - |
$1,589 | 140 | $271 | 8 | - | - | - | - | - | - | - | - |
$1,589 140 kWh |
$271 8 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,510 Cost: - |
$748 | 177,869 | $7,762 | 26 | - | - | - | - | - | - | - | - |
$748 177,869 kWh |
$7,762 26 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $78,900 Cost: $132,800 |
$78,900 | 1,998,900 | - | - | - | - | - | - | - | - | - | - |
$78,900 1,998,900 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $87,200 Cost: $43,600 |
$87,200 | 263,600 | - | - | - | - | - | - | - | - | - | - |
$87,200 263,600 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.2111 INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE |
Savings: $52,540 Cost: $2,200 |
- | - | - | - | - | - | - | - | $52,540 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$52,540 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $46,700 Cost: $46,700 |
$43,500 | 997,000 | $3,200 | 112 | - | - | - | - | - | - | - | - |
$43,500 997,000 kWh |
$3,200 112 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $7,300 Cost: $5,700 |
$6,900 | 157,000 | $400 | 15 | - | - | - | - | - | - | - | - |
$6,900 157,000 kWh |
$400 15 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $664,990 Cost: $2,283,166 |
$444,192 | 6,483,273 | $15,713 | 9,725 | $36,039 | - | $114,735 | - | $52,540 | - | $1,771 | - | $444,192 6,483,273 kWh |
$15,713 9,725 kW-months/year |
$36,039 - $ |
$114,735 - $ |
$52,540 - $ |
$1,771 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Primary Raw Material | Ancillary Material Cost |