Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2008 |
Principal Product | Process Chemicals |
NAICS | 325199 - All Other Basic Organic Chemical Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 32 |
Plant Area (Sq.Ft.) | 49,000 |
Annual Production | 40,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $95,900 | 1,620,000 | kWh | $0.06 |
Electricity Demand | $22 | 4 | kW-months/year | $5.50 |
Electricity Fees | $627 | - | $ | - |
Natural Gas | $46 | 353 | MMBtu | $0.13 |
TOTAL ENERGY COSTS | $96,671 | |||
RECOMMENDED SAVINGS* | $44,233 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,110 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $29 Cost: $10,000 |
- | - | - | - | - | - | $8 | 92,032 | - | - | $21 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8 92,032 Tgal |
- - $ |
$21 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $14,149 Cost: $6,100 |
- | - | - | - | $14,149 | 1,489 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$14,149 1,489 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,932 Cost: $13,049 |
$1,561 | 24,960 | $178 | 5 | - | - | - | - | $1,193 | - | - | - |
$1,561 24,960 kWh |
$178 5 kW-months/year |
- - MMBtu |
- - Tgal |
$1,193 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $23,433 Cost: $257,380 |
$23,433 | 351,000 | - | - | - | - | - | - | - | - | - | - |
$23,433 351,000 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $434 Cost: $12,400 |
$434 | 5,793 | - | - | - | - | - | - | - | - | - | - |
$434 5,793 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,216 Cost: - |
$2,216 | 35,432 | - | - | - | - | - | - | - | - | - | - |
$2,216 35,432 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $699 Cost: $1,398 |
$699 | 10,290 | - | - | - | - | - | - | - | - | - | - |
$699 10,290 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $341 Cost: - |
$341 | 4,992 | - | - | - | - | - | - | - | - | - | - |
$341 4,992 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $44,233 Cost: $300,327 |
$28,684 | 432,467 | $178 | 5 | $14,149 | 1,489 | $8 | 92,032 | $1,193 | - | $21 | - | $28,684 432,467 kWh |
$178 5 kW-months/year |
$14,149 1,489 MMBtu |
$8 92,032 Tgal |
$1,193 - $ |
$21 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,110 Cost: $29,149 |
$1,561 | 24,960 | $178 | 5 | $14,149 | 1,489 | $8 | 92,032 | $1,193 | - | $21 | - | $1,561 24,960 kWh |
$178 5 kW-months/year |
$14,149 1,489 MMBtu |
$8 92,032 Tgal |
$1,193 - $ |
$21 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Water Consumption |