Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2013 |
Principal Product | Wood Pellets |
NAICS | 321999 - All Other Miscellaneous Wood Product Manufacturing |
SIC | 2499 - Wood Products, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 12 |
Plant Area (Sq.Ft.) | 67,000 |
Annual Production | 17,000 Units |
Production Hrs. Annual | 2,315 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $110,082 | 2,213,700 | kWh | $0.05 |
Electricity Demand | $96,840 | 11,703 | kW-months/year | $8.27 |
Electricity Fees | $23,598 | - | $ | - |
Natural Gas | $242,667 | 47,421 | MMBtu | $5.12 |
TOTAL ENERGY COSTS | $473,187 | |||
RECOMMENDED SAVINGS* | $150,134 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $147,407 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $145,630 Cost: $200 |
- | - | - | - | - | - | $130 | 29 | - | - | - | - | $145,500 | - |
- - kWh |
- - kW-months/year |
- - $ |
$130 29 MMBtu |
- - $ |
- - $ |
$145,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,132 Cost: $6,100 |
$580 | 10,805 | $365 | 42 | - | - | - | - | $(-53) | - | $240 | - | - | - |
$580 10,805 kWh |
$365 42 kW-months/year |
- - $ |
- - MMBtu |
$(-53) - $ |
$240 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,727 Cost: $11,025 |
- | - | - | - | $2,727 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,727 - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $645 Cost: $750 |
$645 | 12,015 | - | - | - | - | - | - | - | - | - | - | - | - |
$645 12,015 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $150,134 Cost: $18,075 |
$1,225 | 22,820 | $365 | 42 | $2,727 | - | $130 | 29 | $(-53) | - | $240 | - | $145,500 | - | $1,225 22,820 kWh |
$365 42 kW-months/year |
$2,727 - $ |
$130 29 MMBtu |
$(-53) - $ |
$240 - $ |
$145,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $147,407 Cost: $7,050 |
$1,225 | 22,820 | $365 | 42 | - | - | $130 | 29 | $(-53) | - | $240 | - | $145,500 | - | $1,225 22,820 kWh |
$365 42 kW-months/year |
- - $ |
$130 29 MMBtu |
$(-53) - $ |
$240 - $ |
$145,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | Primary Product |