Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2014 |
Principal Product | Beer |
NAICS | 312120 - Breweries |
SIC | 2082 - Malt Beverages |
Sales | $100,000,000-$500,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 500,000 BBL |
Production Hrs. Annual | 7,488 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $327,714 | 5,554,200 | kWh | $0.06 |
Electricity Demand | $103,276 | 13,380 | kW-months/year | $7.72 |
Electricity Fees | $31,526 | - | $ | - |
Natural Gas | $286,762 | 57,287 | MMBtu | $5.01 |
TOTAL ENERGY COSTS | $2,209,871 | |||
RECOMMENDED SAVINGS* | $831,669 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,708 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $31,057 Cost: $7,123 |
$11,700 | 201,138 | - | - | $19,357 | 3,112 | - | - | - | - | - | - |
$11,700 201,138 kWh |
- - kW-months/year |
$19,357 3,112 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $55,473 Cost: $50,000 |
$(-2,499) | (-42,953) | $(-590) | (-68) | - | - | $42,446 | 3,369 | - | - | $16,116 | - |
$(-2,499) (-42,953) kWh |
$(-590) (-68) kW-months/year |
- - MMBtu |
$42,446 3,369 Tgal |
- - $ |
$16,116 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $5,708 Cost: $7,000 |
$5,708 | 66,374 | - | - | - | - | - | - | - | - | - | - |
$5,708 66,374 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1392 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE |
Savings: $27,166 Cost: $37,500 |
$(-780) | (-13,407) | $(-185) | (-21) | $28,131 | 4,523 | - | - | - | - | - | - |
$(-780) (-13,407) kWh |
$(-185) (-21) kW-months/year |
$28,131 4,523 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4131 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT |
Savings: $712,265 Cost: $3,300,000 |
$(-2,152) | (-36,987) | - | - | - | - | $764,417 | 34,063 | $(-50,000) | - | - | - |
$(-2,152) (-36,987) kWh |
- - kW-months/year |
- - MMBtu |
$764,417 34,063 Tgal |
$(-50,000) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $831,669 Cost: $3,401,623 |
$11,977 | 174,165 | $(-775) | (-89) | $47,488 | 7,635 | $806,863 | 37,432 | $(-50,000) | - | $16,116 | - | $11,977 174,165 kWh |
$(-775) (-89) kW-months/year |
$47,488 7,635 MMBtu |
$806,863 37,432 Tgal |
$(-50,000) - $ |
$16,116 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,708 Cost: $7,000 |
$5,708 | 66,374 | - | - | - | - | - | - | - | - | - | - | $5,708 66,374 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption |