Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2014 |
Principal Product | Plywood |
NAICS | 321212 - Softwood Veneer and Plywood Manufacturing |
SIC | 2493 - Reconstituted Wood Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 390 |
Plant Area (Sq.Ft.) | 6,423,000 |
Annual Production | 316,955,697 Thousand Feet |
Production Hrs. Annual | 8,712 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,532,514 | 31,884,000 | kWh | $0.05 |
Electricity Demand | $507,220 | 119,779 | kW-months/year | $4.23 |
Electricity Fees | $84,389 | - | $ | - |
Natural Gas | $45,799 | 5,923 | MMBtu | $7.73 |
LPG | $30,194 | 1,824 | MMBtu | $16.55 |
TOTAL ENERGY COSTS | $2,200,116 | |||
RECOMMENDED SAVINGS* | $166,691 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $142,697 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Electricity Usage | Electricity Demand | LPG | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $131,605 Cost: $242,261 |
$104,903 | 2,081,399 | $26,702 | 5,076 | - | - |
$104,903 2,081,399 kWh |
$26,702 5,076 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $2,455 Cost: - |
$2,455 | 46,591 | - | - | - | - |
$2,455 46,591 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $1,298 Cost: $1,020 |
$1,298 | 25,955 | - | - | - | - |
$1,298 25,955 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL |
Savings: $20,241 Cost: $67,550 |
$(-8,835) | (-154,290) | $(-1,118) | (-213) | $30,194 | 1,824 |
$(-8,835) (-154,290) kWh |
$(-1,118) (-213) kW-months/year |
$30,194 1,824 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $11,092 Cost: $12,092 |
$9,689 | 193,702 | $1,403 | 267 | - | - |
$9,689 193,702 kWh |
$1,403 267 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $166,691 Cost: $322,923 |
$109,510 | 2,193,357 | $26,987 | 5,130 | $30,194 | 1,824 | $109,510 2,193,357 kWh |
$26,987 5,130 kW-months/year |
$30,194 1,824 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $142,697 Cost: $254,353 |
$114,592 | 2,275,101 | $28,105 | 5,343 | - | - | $114,592 2,275,101 kWh |
$28,105 5,343 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Electricity Usage | Electricity Demand | LPG |