Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2015 |
Principal Product | Laboratory Equipment |
NAICS | 334516 - Analytical Laboratory Instrument Manufacturing |
SIC | 3821 - Laboratory Apparatus And Furniture |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 5,777 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $49,598 | 831,735 | kWh | $0.06 |
Electricity Demand | $9,747 | 3,238 | kW-months/year | $3.01 |
Electricity Fees | $14,888 | - | $ | - |
Natural Gas | $45,747 | 5,140 | MMBtu | $8.90 |
TOTAL ENERGY COSTS | $122,589 | |||
RECOMMENDED SAVINGS* | $64,012 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,010 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $20,348 Cost: $2,295 |
- | - | - | - | - | - | - | - | - | - | $20,348 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$20,348 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $23,922 Cost: $24,660 |
- | - | - | - | $23,922 | 3,847 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$23,922 3,847 MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.7312 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS |
Savings: $719 Cost: $1,200 |
- | - | - | - | - | - | $719 | 20,628 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$719 20,628 gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,001 Cost: $2,678 |
$822 | 13,593 | - | - | - | - | - | - | $47 | - | - | - | $132 | - |
$822 13,593 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$47 - $ |
- - $ |
$132 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3111 HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE |
Savings: $1,291 Cost: $4,404 |
$1,291 | 21,480 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,291 21,480 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $16,731 Cost: $135,510 |
$16,649 | 276,948 | $82 | 27 | - | - | - | - | - | - | - | - | - | - |
$16,649 276,948 kWh |
$82 27 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $64,012 Cost: $170,747 |
$18,762 | 312,021 | $82 | 27 | $23,922 | 3,847 | $719 | 20,628 | $47 | - | $20,348 | - | $132 | - | $18,762 312,021 kWh |
$82 27 kW-months/year |
$23,922 3,847 MMBtu |
$719 20,628 gal |
$47 - $ |
$20,348 - $ |
$132 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,010 Cost: $5,604 |
$1,291 | 21,480 | - | - | - | - | $719 | 20,628 | - | - | - | - | - | - | $1,291 21,480 kWh |
- - kW-months/year |
- - MMBtu |
$719 20,628 gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost |