Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2015
Principal Product Soup
NAICS 311991 - Perishable Prepared Food Manufacturing
SIC 2032 - Canned Specialties
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 220,000
Annual Production 72,000,000 Units
Production Hrs. Annual 5,200
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $910,245 13,658,400 kWh $0.07
Electricity Demand $118,711 27,607 kW-months/year $4.30
Electricity Fees $425,415 - $ -
Natural Gas $449,521 85,552 MMBtu $5.25
TOTAL ENERGY COSTS $1,903,892
RECOMMENDED SAVINGS* $481,151 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,161
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Increase in Production Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Increase in Production
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ %
01: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$26,151
Cost:
-
$26,151 393,362 - - - - - - - - - - $26,151
393,362
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,161
Cost:
$1,000
- - - - $4,161 827 - - - - - - -
-
kWh
-
-
kW-months/year
$4,161
827
MMBtu
-
-
$
-
-
$
-
-
%
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$20,211
Cost:
$1,000
$20,211 304,018 - - - - - - - - - - $20,211
304,018
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
04: 2.8227 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION Savings:
$175,008
Cost:
$188,400
$(-26,592) (-400,000) - - - - $93,600 - - - $108,000 - $(-26,592)
(-400,000)
kWh
-
-
kW-months/year
-
-
MMBtu
$93,600
-
$
-
-
$
$108,000
-
%
05: 2.2127 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM Savings:
$15,571
Cost:
$19,050
- - - - $15,571 3,096 - - - - - - -
-
kWh
-
-
kW-months/year
$15,571
3,096
MMBtu
-
-
$
-
-
$
-
-
%
06: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$180,695
Cost:
$251,760
- - - - - - - - $180,695 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
$180,695
-
$
-
-
%
07: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$51,916
Cost:
$126,000
$45,099 678,378 $6,817 1,585 - - - - - - - - $45,099
678,378
kWh
$6,817
1,585
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$4,958
Cost:
$7,816
- - - - $4,958 887 - - - - - - -
-
kWh
-
-
kW-months/year
$4,958
887
MMBtu
-
-
$
-
-
$
-
-
%
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$2,480
Cost:
$20,979
$2,462 37,041 $18 4 - - - - - - - - $2,462
37,041
kWh
$18
4
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
TOTAL RECOMMENDED Savings:
$481,151
Cost:
$616,005
$67,331 1,012,799 $6,835 1,589 $24,690 4,810 $93,600 - $180,695 - $108,000 - $67,331
1,012,799
kWh
$6,835
1,589
kW-months/year
$24,690
4,810
MMBtu
$93,600
-
$
$180,695
-
$
$108,000
-
%
TOTAL IMPLEMENTED Savings:
$4,161
Cost:
$1,000
- - - - $4,161 827 - - - - - - -
-
kWh
-
-
kW-months/year
$4,161
827
MMBtu
-
-
$
-
-
$
-
-
%
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ %
Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Increase in Production Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Increase in Production