Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2018 |
Principal Product | Bus Maintenance |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $5,000,000-$10,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 94,600 |
Annual Production | 107 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $80,852 | 1,814,600 | kWh | $0.04 |
Electricity Demand | $19,387 | 3,378 | kW-months/year | $5.74 |
Electricity Fees | $2,131 | - | $ | - |
Natural Gas | $53,575 | 6,504 | MMBtu | $8.24 |
TOTAL ENERGY COSTS | $155,945 | |||
RECOMMENDED SAVINGS* | $66,197 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,983 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $32,214 Cost: $597 |
- | - | - | - | - | - | $32,214 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$32,214 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $18,374 Cost: $9,440 |
- | - | $18,374 | 2,880 | - | - | - | - |
- - kWh |
$18,374 2,880 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $12,461 Cost: $22,850 |
$15,498 | 358,176 | - | - | $(-3,037) | (-370) | - | - |
$15,498 358,176 kWh |
- - kW-months/year |
$(-3,037) (-370) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $3,148 Cost: $325 |
$1,073 | 24,790 | $2,075 | 325 | - | - | - | - |
$1,073 24,790 kWh |
$2,075 325 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $66,197 Cost: $33,212 |
$16,571 | 382,966 | $20,449 | 3,205 | $(-3,037) | (-370) | $32,214 | - | $16,571 382,966 kWh |
$20,449 3,205 kW-months/year |
$(-3,037) (-370) MMBtu |
$32,214 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,983 Cost: $32,615 |
$16,571 | 382,966 | $20,449 | 3,205 | $(-3,037) | (-370) | - | - | $16,571 382,966 kWh |
$20,449 3,205 kW-months/year |
$(-3,037) (-370) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |