Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2019 |
Principal Product | Sand, gravel, concrete |
NAICS | 212321 - Construction Sand and Gravel Mining |
SIC | 1442 - Construction Sand And Gravel |
Sales | $5,000,000-$10,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 577,800 |
Annual Production | 350,000 Tons |
Production Hrs. Annual | 2,600 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $34,188 | 857,737 | kWh | $0.04 |
Electricity Demand | $54,335 | 8,892 | kW-months/year | $6.11 |
Electricity Fees | $38,832 | - | $ | - |
LPG | $16,169 | 984 | MMBtu | $16.43 |
TOTAL ENERGY COSTS | $143,524 | |||
RECOMMENDED SAVINGS* | $34,762 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $15,651 Cost: $5,000 |
- | - | - | - | - | - | $4,087 | 170 | - | - | $4,087 | - | - | - | $7,477 | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,087 170 MMBtu |
- - $ |
$4,087 - $ |
- - $ |
$7,477 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.426 MODIFY WORKLOAD |
Savings: $13,223 Cost: $18,824 |
- | - | - | - | - | - | - | - | $13,223 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$13,223 - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,201 Cost: - |
$502 | 8,178 | $1,699 | 213 | - | - | - | - | - | - | - | - | - | - | - | - |
$502 8,178 kWh |
$1,699 213 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,657 Cost: $9,364 |
- | - | - | - | $2,657 | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,657 - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,030 Cost: $2,058 |
$858 | 12,233 | $246 | 43 | - | - | - | - | - | - | $50 | - | $(-124) | - | - | - |
$858 12,233 kWh |
$246 43 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$50 - $ |
$(-124) - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,762 Cost: $35,246 |
$1,360 | 20,411 | $1,945 | 256 | $2,657 | - | $4,087 | 170 | $13,223 | - | $4,137 | - | $(-124) | - | $7,477 | - | $1,360 20,411 kWh |
$1,945 256 kW-months/year |
$2,657 - $ |
$4,087 170 MMBtu |
$13,223 - $ |
$4,137 - $ |
$(-124) - $ |
$7,477 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | LPG | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production |