Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2024 |
Principal Product | Manufactured homes |
NAICS | 321991 - Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451 - Mobile Homes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 212 |
Plant Area (Sq.Ft.) | 168,000 |
Annual Production | 880 Units |
Production Hrs. Annual | 6,120 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $48,391 | 720,914 | kWh | $0.07 |
Electricity Demand | $40,784 | 2,992 | kW-months/year | $13.63 |
Electricity Fees | $5,097 | - | $ | - |
Natural Gas | $19,906 | 1,856 | MMBtu | $10.73 |
LPG | $14,463 | 621 | MMBtu | $23.28 |
TOTAL ENERGY COSTS | $128,641 | |||
RECOMMENDED SAVINGS* | $51,372 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,236 Cost: $1,629 |
- | - | - | - | $1,236 | 113 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,236 113 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,287 Cost: $5,523 |
$2,287 | 34,077 | - | - | - | - | - | - | - | - | - | - |
$2,287 34,077 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $20,545 Cost: $92,473 |
$(-9,181) | (-136,782) | - | - | - | - | $14,463 | 621 | $12,590 | - | $2,673 | - |
$(-9,181) (-136,782) kWh |
- - kW-months/year |
- - MMBtu |
$14,463 621 MMBtu |
$12,590 - $ |
$2,673 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $12,662 Cost: $67,250 |
$8,246 | 122,809 | $4,416 | 324 | - | - | - | - | - | - | - | - |
$8,246 122,809 kWh |
$4,416 324 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,153 Cost: $7,546 |
$1,153 | 17,180 | - | - | - | - | - | - | - | - | - | - |
$1,153 17,180 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $13,489 Cost: $12,623 |
$6,898 | 102,765 | $6,591 | 484 | - | - | - | - | - | - | - | - |
$6,898 102,765 kWh |
$6,591 484 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $51,372 Cost: $187,044 |
$9,403 | 140,049 | $11,007 | 808 | $1,236 | 113 | $14,463 | 621 | $12,590 | - | $2,673 | - | $9,403 140,049 kWh |
$11,007 808 kW-months/year |
$1,236 113 MMBtu |
$14,463 621 MMBtu |
$12,590 - $ |
$2,673 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | Administrative Changes |