Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2024 |
Principal Product | Treated Wastewater |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $5,000,000-$10,000,000 |
# of Employees | 7 |
Plant Area (Sq.Ft.) | 1,608,337 |
Annual Production | 839,500 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $84,261 | 1,004,378 | kWh | $0.08 |
Electricity Demand | $20,547 | 2,764 | kW-months/year | $7.43 |
Electricity Fees | $10,483 | - | $ | - |
Natural Gas | $33,857 | 3,100 | MMBtu | $10.92 |
TOTAL ENERGY COSTS | $149,148 | |||
RECOMMENDED SAVINGS* | $66,895 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3322 USE EXISTING DAM TO GENERATE ELECTRICITY |
Savings: $4,211 Cost: $17,825 |
$4,211 | 62,016 | - | - | - | - | - | - |
$4,211 62,016 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $2,639 Cost: $227 |
$2,639 | 31,454 | - | - | - | - | - | - |
$2,639 31,454 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.463 MODIFY FACILITY TO AVOID EXCESS MAINTENANCE COSTS |
Savings: $7,711 Cost: $22,822 |
$191 | 2,282 | - | - | $3,200 | - | $4,320 | - |
$191 2,282 kWh |
- - kW-months/year |
$3,200 - $ |
$4,320 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $3,405 Cost: $16,073 |
$3,066 | 36,551 | $339 | 46 | - | - | - | - |
$3,066 36,551 kWh |
$339 46 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR |
Savings: $5,114 Cost: $43,821 |
$4,561 | 54,372 | $553 | 75 | - | - | - | - |
$4,561 54,372 kWh |
$553 75 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $43,815 Cost: $607,740 |
$37,841 | 451,033 | $5,974 | 804 | - | - | - | - |
$37,841 451,033 kWh |
$5,974 804 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $66,895 Cost: $708,508 |
$52,509 | 637,708 | $6,866 | 924 | $3,200 | - | $4,320 | - | $52,509 637,708 kWh |
$6,866 924 kW-months/year |
$3,200 - $ |
$4,320 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Primary Raw Material | Ancillary Material Cost |