IAC logo
IAC Assessment: RU0006
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: RU0006
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Rutgers, State Univ. of NJ
Assessment Year 1987
Principal Product SILK SCREENING ON BOTTLE
NAICS n/a
SIC 2752 - Commercial Printing, Lithographic
Sales $1,000,000-$5,000,000
# of Employees 52
Plant Area (Sq.Ft.) 0
Annual Production 100,000 Pieces
Production Hrs. Annual 6,000
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $116,166 1,441,090 kWh $0.08
Natural Gas $124,444 21,007 MMBtu $5.92
TOTAL ENERGY COSTS $240,610
RECOMMENDED SAVINGS* $25,519 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,530
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES Savings:
$4,140
Cost:
$396
- - $3,255 552 $885 - -
-
kWh
$3,255
552
MMBtu
$885
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$3,147
Cost:
$648
- - $3,147 534 - - -
-
kWh
$3,147
534
MMBtu
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,672
Cost:
-
$2,672 33,411 - - - - $2,672
33,411
kWh
-
-
MMBtu
-
-
$
04: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$832
Cost:
-
$832 10,551 - - - - $832
10,551
kWh
-
-
MMBtu
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$5,154
Cost:
$5,600
$5,154 64,478 - - - - $5,154
64,478
kWh
-
-
MMBtu
-
-
$
06: 2.2441 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT Savings:
$8,856
Cost:
$9,500
- - $8,856 1,501 - - -
-
kWh
$8,856
1,501
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$718
Cost:
$1,204
$718 13,775 - - - - $718
13,775
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$25,519
Cost:
$17,348
$9,376 122,215 $15,258 2,587 $885 - $9,376
122,215
kWh
$15,258
2,587
MMBtu
$885
-
$
TOTAL IMPLEMENTED Savings:
$7,530
Cost:
$1,600
$3,390 47,186 $3,255 552 $885 - $3,390
47,186
kWh
$3,255
552
MMBtu
$885
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes