IAC logo
IAC Assessment: RU0144
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: RU0144
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Rutgers, State Univ. of NJ
Assessment Year 1992
Principal Product RAIN GUTTERS
NAICS n/a
SIC 3444 - Sheet Metalwork
Sales $10,000,000-$50,000,000
# of Employees 57
Plant Area (Sq.Ft.) 0
Annual Production 41,700,000 Pieces
Production Hrs. Annual 2,275
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $73,843 563,013 kWh $0.13
Natural Gas $25,357 3,896 MMBtu $6.51
TOTAL ENERGY COSTS $99,200
RECOMMENDED SAVINGS* $8,833 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,212
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$743
Cost:
$800
$743 5,862 - - - - $743
5,862
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$572
Cost:
$66
$716 5,569 - - $(-144) - $716
5,569
kWh
-
-
MMBtu
$(-144)
-
$
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$640
Cost:
$479
$640 4,982 - - - - $640
4,982
kWh
-
-
MMBtu
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$754
Cost:
$4,750
$754 5,862 - - - - $754
5,862
kWh
-
-
MMBtu
-
-
$
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$4,207
Cost:
-
- - $4,207 1,773 - - -
-
kWh
$4,207
1,773
MMBtu
-
-
$
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$1,917
Cost:
$2,520
$(-288) (-2,345) $2,205 339 - - $(-288)
(-2,345)
kWh
$2,205
339
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$8,833
Cost:
$8,615
$2,565 19,930 $6,412 2,112 $(-144) - $2,565
19,930
kWh
$6,412
2,112
MMBtu
$(-144)
-
$
TOTAL IMPLEMENTED Savings:
$1,212
Cost:
$545
$1,356 10,551 - - $(-144) - $1,356
10,551
kWh
-
-
MMBtu
$(-144)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes