Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1991
Principal Product POWER SUPPLY EQUIPMENT
NAICS n/a
SIC 3629 - Electrical Industrial Apparatus, Nec
Sales $10,000,000-$50,000,000
# of Employees 130
Plant Area (Sq.Ft.) 0
Annual Production 1,785 Pieces
Production Hrs. Annual 4,335
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $157,804 1,926,143 kWh $0.08
Natural Gas $6,047 941 MMBtu $6.43
TOTAL ENERGY COSTS $163,851
RECOMMENDED SAVINGS* $35,289 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE Savings:
$1,469
Cost:
$468
$1,469 17,878 - - $1,469
17,878
kWh
-
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$25
Cost:
$22
$25 293 - - $25
293
kWh
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$887
Cost:
$832
$546 6,741 $341 - $546
6,741
kWh
$341
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,661
Cost:
$3,360
$408 4,982 $1,253 - $408
4,982
kWh
$1,253
-
$
05: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$287
Cost:
$600
$265 3,224 $22 - $265
3,224
kWh
$22
-
$
06: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,627
Cost:
$3,600
$1,441 17,585 $186 - $1,441
17,585
kWh
$186
-
$
07: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$12,712
Cost:
$31,740
$11,717 143,025 $995 - $11,717
143,025
kWh
$995
-
$
08: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$6,433
Cost:
$22,980
$5,621 68,581 $812 - $5,621
68,581
kWh
$812
-
$
09: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$10,188
Cost:
$18,000
$10,188 124,267 - - $10,188
124,267
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$35,289
Cost:
$81,602
$31,680 386,576 $3,609 - $31,680
386,576
kWh
$3,609
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
$
Savings
Cost
$ kWh $ $