IAC logo
IAC Assessment: SD0169
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0169
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1997
Principal Product Computer Printers
NAICS n/a
SIC 3577 - Computer Peripheral Equipment, Nec
Sales $50,000,000-$100,000,000
# of Employees 250
Plant Area (Sq.Ft.) 90,000
Annual Production 15,600 Pieces
Production Hrs. Annual 5,750
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $284,252 3,951,348 kWh $0.07
Electricity Demand $72,090 9,003 kW-months/year $8.01
Natural Gas $3,124 501 MMBtu $6.24
TOTAL ENERGY COSTS $359,466
RECOMMENDED SAVINGS* $88,416 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $46,655
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Liquid (non-haz) Other Liquid (haz) Administrative Changes Electricity Usage Electricity Demand Other Liquid (non-haz) Other Liquid (haz) Administrative Changes
$ kWh $ kW-months/year $ gal $ gal $ $
01: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$20,154
Cost:
$3,300
$20,154 288,394 - - - - - - - - $20,154
288,394
kWh
-
-
kW-months/year
-
-
gal
-
-
gal
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$9,714
Cost:
$11,700
$8,423 117,233 $1,291 161 - - - - - - $8,423
117,233
kWh
$1,291
161
kW-months/year
-
-
gal
-
-
gal
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,459
Cost:
-
$1,259 17,585 $200 25 - - - - - - $1,259
17,585
kWh
$200
25
kW-months/year
-
-
gal
-
-
gal
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$941
Cost:
$469
$770 10,551 $171 21 - - - - - - $770
10,551
kWh
$171
21
kW-months/year
-
-
gal
-
-
gal
-
-
$
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$1,809
Cost:
$4,110
$1,085 14,947 $724 90 - - - - - - $1,085
14,947
kWh
$724
90
kW-months/year
-
-
gal
-
-
gal
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,082
Cost:
$1,845
$129 37,808 $953 119 - - - - - - $129
37,808
kWh
$953
119
kW-months/year
-
-
gal
-
-
gal
-
-
$
07: 3.8224 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS Savings:
$1,894
Cost:
-
- - - - - - $1,894 700 - - -
-
kWh
-
-
kW-months/year
-
-
gal
$1,894
700
gal
-
-
$
08: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS Savings:
$11,496
Cost:
$3,480
- - - - - - - - $11,496 - -
-
kWh
-
-
kW-months/year
-
-
gal
-
-
gal
$11,496
-
$
09: 3.1171 CHANGE PRODUCT SPECS Savings:
$39,867
Cost:
-
- - - - $39,867 6,500 - - - - -
-
kWh
-
-
kW-months/year
$39,867
6,500
gal
-
-
gal
-
-
$
TOTAL RECOMMENDED Savings:
$88,416
Cost:
$24,904
$31,820 486,518 $3,339 416 $39,867 6,500 $1,894 700 $11,496 - $31,820
486,518
kWh
$3,339
416
kW-months/year
$39,867
6,500
gal
$1,894
700
gal
$11,496
-
$
TOTAL IMPLEMENTED Savings:
$46,655
Cost:
$24,904
$31,820 486,518 $3,339 416 - - - - $11,496 - $31,820
486,518
kWh
$3,339
416
kW-months/year
-
-
gal
-
-
gal
$11,496
-
$
Savings
Cost
$ kWh $ kW-months/year $ gal $ gal $ $
Electricity Usage Electricity Demand Other Liquid (non-haz) Other Liquid (haz) Administrative Changes Electricity Usage Electricity Demand Other Liquid (non-haz) Other Liquid (haz) Administrative Changes