Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1997 |
Principal Product | Transformers, inductors and electric components for major in |
NAICS | n/a |
SIC | 3677 - Electronic Coils And Transformers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 27,000 |
Annual Production | 3,200 Pieces |
Production Hrs. Annual | 2,167 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $82,407 | 1,009,672 | kWh | $0.08 |
Electricity Demand | $28,948 | 3,566 | kW-months/year | $8.12 |
Natural Gas | $1,991 | 263 | MMBtu | $7.57 |
TOTAL ENERGY COSTS | $113,346 | |||
RECOMMENDED SAVINGS* | $34,746 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,349 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $721 Cost: $1,200 |
$558 | 6,741 | $163 | 20 | - | - | - | - |
$558 6,741 kWh |
$163 20 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,934 Cost: $17,722 |
$6,327 | 77,081 | $2,607 | 321 | - | - | - | - |
$6,327 77,081 kWh |
$2,607 321 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $15,429 Cost: $16,085 |
$10,936 | 133,353 | $4,493 | 553 | - | - | - | - |
$10,936 133,353 kWh |
$4,493 553 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $3,120 Cost: $2,000 |
- | - | - | - | - | - | $3,120 | - |
- - kWh |
- - kW-months/year |
- - gal |
$3,120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.8224 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS |
Savings: $4,145 Cost: - |
- | - | - | - | $4,145 | 550 | - | - |
- - kWh |
- - kW-months/year |
$4,145 550 gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $2,397 Cost: $320 |
- | - | - | - | - | - | $2,397 | - |
- - kWh |
- - kW-months/year |
- - gal |
$2,397 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,746 Cost: $37,327 |
$17,821 | 217,175 | $7,263 | 894 | $4,145 | 550 | $5,517 | - | $17,821 217,175 kWh |
$7,263 894 kW-months/year |
$4,145 550 gal |
$5,517 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,349 Cost: $37,007 |
$17,821 | 217,175 | $7,263 | 894 | $4,145 | 550 | $3,120 | - | $17,821 217,175 kWh |
$7,263 894 kW-months/year |
$4,145 550 gal |
$3,120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes |