Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1997 |
Principal Product | Produce stamp out metal parts with drop hammer |
NAICS | n/a |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 62,000 Pieces |
Production Hrs. Annual | 4,950 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $28,895 | 344,959 | kWh | $0.08 |
Electricity Demand | $23,808 | 1,934 | kW-months/year | $12.31 |
Natural Gas | $67,383 | 15,804 | MMBtu | $4.26 |
TOTAL ENERGY COSTS | $120,086 | |||
RECOMMENDED SAVINGS* | $129,530 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $108,397 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $11,371 Cost: $2,170 |
- | - | - | - | $11,371 | 2,644 | - | - | - | - |
- - kWh |
- - kW-months/year |
$11,371 2,644 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $4,451 Cost: $3,200 |
- | - | - | - | $4,451 | 1,035 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,451 1,035 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,591 Cost: $1,830 |
- | - | - | - | $1,591 | 370 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,591 370 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $820 Cost: $1,500 |
$446 | 5,275 | $374 | 26 | - | - | - | - | - | - |
$446 5,275 kWh |
$374 26 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $710 Cost: $2,025 |
$487 | 5,862 | $223 | 18 | - | - | - | - | - | - |
$487 5,862 kWh |
$223 18 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $806 Cost: $1,030 |
$535 | 6,155 | $271 | 22 | - | - | - | - | - | - |
$535 6,155 kWh |
$271 22 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7197 USE ULTRASONIC CLEANING |
Savings: $53,556 Cost: $1,140 |
- | - | - | - | - | - | $53,556 | 14,550 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$53,556 14,550 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8224 CONVERT TO LESS TOXIC HYDROCARBON CLEANERS |
Savings: $53,325 Cost: - |
- | - | - | - | - | - | $53,325 | 4,925 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$53,325 4,925 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $2,900 Cost: $8,500 |
- | - | - | - | - | - | - | - | $2,900 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$2,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $129,530 Cost: $21,395 |
$1,468 | 17,292 | $868 | 66 | $17,413 | 4,049 | $106,881 | 19,475 | $2,900 | - | $1,468 17,292 kWh |
$868 66 kW-months/year |
$17,413 4,049 MMBtu |
$106,881 19,475 gal |
$2,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $108,397 Cost: $4,195 |
$1,022 | 12,017 | $494 | 40 | - | - | $106,881 | 19,475 | - | - | $1,022 12,017 kWh |
$494 40 kW-months/year |
- - MMBtu |
$106,881 19,475 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes |