Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1998 |
Principal Product | Bedspreads and Bed sets |
NAICS | n/a |
SIC | 2392 - Housefurnishings, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 380 |
Plant Area (Sq.Ft.) | 175,000 |
Annual Production | 12,500,000 Units |
Production Hrs. Annual | 4,000 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $86,609 | 1,258,206 | kWh | $0.07 |
Electricity Demand | $25,727 | 3,142 | kW-months/year | $8.19 |
TOTAL ENERGY COSTS | $112,336 | |||
RECOMMENDED SAVINGS* | $56,419 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $36,860 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,848 Cost: $2,848 |
$2,100 | 30,481 | $748 | 91 | - | - | - | - |
$2,100 30,481 kWh |
$748 91 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,078 Cost: $1,500 |
$2,078 | 30,188 | - | - | - | - | - | - |
$2,078 30,188 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,481 Cost: - |
$1,092 | 15,826 | $389 | 47 | - | - | - | - |
$1,092 15,826 kWh |
$389 47 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,411 Cost: $4,495 |
$887 | 12,896 | $524 | 64 | - | - | - | - |
$887 12,896 kWh |
$524 64 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $1,914 Cost: $3,160 |
$1,203 | 17,585 | $711 | 87 | - | - | - | - |
$1,203 17,585 kWh |
$711 87 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $10,800 Cost: $5,000 |
- | - | - | - | $10,800 | 86,400 | - | - |
- - kWh |
- - kW-months/year |
$10,800 86,400 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $687 Cost: - |
- | - | - | - | $687 | 27,500 | - | - |
- - kWh |
- - kW-months/year |
$687 27,500 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $16,000 Cost: $10,000 |
- | - | - | - | - | - | $16,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$16,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $3,200 Cost: $3,000 |
- | - | - | - | - | - | $3,200 | - |
- - kWh |
- - kW-months/year |
- - lb |
$3,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $16,000 Cost: $4,000 |
- | - | - | - | - | - | $16,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$16,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $56,419 Cost: $34,003 |
$7,360 | 106,976 | $2,372 | 289 | $11,487 | 113,900 | $35,200 | - | $7,360 106,976 kWh |
$2,372 289 kW-months/year |
$11,487 113,900 lb |
$35,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $36,860 Cost: $28,503 |
$4,190 | 60,962 | $1,983 | 242 | $11,487 | 113,900 | $19,200 | - | $4,190 60,962 kWh |
$1,983 242 kW-months/year |
$11,487 113,900 lb |
$19,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes |