IAC logo
IAC Assessment: SD0227
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0227
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1999
Principal Product Analytical Intruments
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 60,000
Annual Production 200 Pieces
Production Hrs. Annual 2,210
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $54,038 757,327 kWh $0.07
Electricity Demand $17,554 2,119 kW-months/year $8.28
Natural Gas $2,690 451 MMBtu $5.96
TOTAL ENERGY COSTS $76,272
RECOMMENDED SAVINGS* $34,502 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,465
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Administrative Changes Electricity Usage Electricity Demand Solid Waste (non-haz) Administrative Changes
$ kWh $ kW-months/year $ lb $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,324
Cost:
$15,387
$2,990 41,911 $1,334 161 - - - - $2,990
41,911
kWh
$1,334
161
kW-months/year
-
-
lb
-
-
$
02: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$6,037
Cost:
$10,200
$4,175 58,617 $1,862 225 - - - - $4,175
58,617
kWh
$1,862
225
kW-months/year
-
-
lb
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,775
Cost:
$1,374
$759 10,551 $1,016 123 - - - - $759
10,551
kWh
$1,016
123
kW-months/year
-
-
lb
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$376
Cost:
-
$146 2,052 $230 28 - - - - $146
2,052
kWh
$230
28
kW-months/year
-
-
lb
-
-
$
05: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS Savings:
$3,990
Cost:
-
- - - - $3,990 1,420 - - -
-
kWh
-
-
kW-months/year
$3,990
1,420
lb
-
-
$
06: 4.522 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE Savings:
$18,000
Cost:
$6,304
- - - - - - $18,000 - -
-
kWh
-
-
kW-months/year
-
-
lb
$18,000
-
$
TOTAL RECOMMENDED Savings:
$34,502
Cost:
$33,265
$8,070 113,131 $4,442 537 $3,990 1,420 $18,000 - $8,070
113,131
kWh
$4,442
537
kW-months/year
$3,990
1,420
lb
$18,000
-
$
TOTAL IMPLEMENTED Savings:
$10,465
Cost:
$16,761
$3,895 54,514 $2,580 312 $3,990 1,420 - - $3,895
54,514
kWh
$2,580
312
kW-months/year
$3,990
1,420
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $
Electricity Usage Electricity Demand Solid Waste (non-haz) Administrative Changes Electricity Usage Electricity Demand Solid Waste (non-haz) Administrative Changes