Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1999 |
Principal Product | In vitro diagnostics |
NAICS | n/a |
SIC | 2835 - Diagnostic Substances |
Sales | $5,000,000-$10,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 20,000 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 2,250 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $37,590 | 861,665 | kWh | $0.04 |
Electricity Demand | $36,795 | 1,837 | kW-months/year | $20.03 |
Natural Gas | $15,128 | 2,689 | MMBtu | $5.63 |
TOTAL ENERGY COSTS | $90,573 | |||
RECOMMENDED SAVINGS* | $22,316 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,694 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Raw Material | Electricity Usage | Electricity Demand | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,674 Cost: $10,286 |
$3,486 | 80,012 | $4,188 | 307 | - | - |
$3,486 80,012 kWh |
$4,188 307 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $7,622 Cost: $3,600 |
$4,543 | 104,338 | $3,079 | 157 | - | - |
$4,543 104,338 kWh |
$3,079 157 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.311 SCHEDULE DELIVERIES ACCORDING TO DEMAND |
Savings: $7,020 Cost: - |
- | - | - | - | $7,020 | - |
- - kWh |
- - kW-months/year |
$7,020 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,316 Cost: $13,886 |
$8,029 | 184,350 | $7,267 | 464 | $7,020 | - | $8,029 184,350 kWh |
$7,267 464 kW-months/year |
$7,020 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,694 Cost: $10,286 |
$3,486 | 80,012 | $4,188 | 307 | $7,020 | - | $3,486 80,012 kWh |
$4,188 307 kW-months/year |
$7,020 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Raw Material | Electricity Usage | Electricity Demand | Primary Raw Material |