Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1999 |
Principal Product | Medical devices |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 82,000 |
Annual Production | 643 Thousand Gallons |
Production Hrs. Annual | 8,568 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $330,409 | 6,316,237 | kWh | $0.05 |
Electricity Demand | $110,403 | 11,750 | kW-months/year | $9.40 |
Electricity Fees | $4,308 | - | $ | - |
TOTAL ENERGY COSTS | $448,983 | |||
RECOMMENDED SAVINGS* | $119,756 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,313 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $8,010 Cost: $11,160 |
$5,970 | 114,302 | $2,040 | 217 | - | - | - | - |
$5,970 114,302 kWh |
$2,040 217 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,708 Cost: $21,250 |
$6,285 | 120,164 | $1,423 | 152 | - | - | - | - |
$6,285 120,164 kWh |
$1,423 152 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,337 Cost: $2,500 |
$2,076 | 39,859 | $261 | 28 | - | - | - | - |
$2,076 39,859 kWh |
$261 28 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS |
Savings: $6,905 Cost: $7,400 |
$3,365 | 64,478 | $3,540 | 377 | - | - | - | - |
$3,365 64,478 kWh |
$3,540 377 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $4,487 Cost: $240 |
$3,585 | 68,581 | $902 | 96 | - | - | - | - |
$3,585 68,581 kWh |
$902 96 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $3,920 Cost: $8,500 |
- | - | - | - | $3,920 | - | - | - |
- - kWh |
- - kW-months/year |
$3,920 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $1,595 Cost: $7,000 |
- | - | - | - | - | - | $1,595 | - |
- - kWh |
- - kW-months/year |
- - lb |
$1,595 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $63,374 Cost: $33,460 |
- | - | - | - | - | - | $63,374 | - |
- - kWh |
- - kW-months/year |
- - lb |
$63,374 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $21,420 Cost: $1,416 |
- | - | - | - | - | - | $21,420 | - |
- - kWh |
- - kW-months/year |
- - lb |
$21,420 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $119,756 Cost: $92,926 |
$21,281 | 407,384 | $8,166 | 870 | $3,920 | - | $86,389 | - | $21,281 407,384 kWh |
$8,166 870 kW-months/year |
$3,920 - lb |
$86,389 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,313 Cost: $39,410 |
$12,255 | 234,466 | $3,463 | 369 | - | - | $1,595 | - | $12,255 234,466 kWh |
$3,463 369 kW-months/year |
- - lb |
$1,595 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product |