Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1999 |
Principal Product | Medical devices for surgery |
NAICS | n/a |
SIC | 3061 - Mechanical Rubber Goods |
Sales | $10,000,000-$50,000,000 |
# of Employees | 315 |
Plant Area (Sq.Ft.) | 57,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 4,125 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $86,449 | 1,091,149 | kWh | $0.08 |
Electricity Demand | $34,940 | 2,405 | kW-months/year | $14.53 |
TOTAL ENERGY COSTS | $121,389 | |||
RECOMMENDED SAVINGS* | $189,154 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,069 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,609 Cost: $25,688 |
$13,552 | 171,161 | $6,057 | 417 | - | - | - | - | - | - |
$13,552 171,161 kWh |
$6,057 417 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $26,750 Cost: $21,265 |
$18,486 | 233,294 | $8,264 | 569 | - | - | - | - | - | - |
$18,486 233,294 kWh |
$8,264 569 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $6,768 Cost: $13,000 |
$4,458 | 56,272 | $2,310 | 159 | - | - | - | - | - | - |
$4,458 56,272 kWh |
$2,310 159 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,069 Cost: $1,425 |
$558 | 7,034 | $511 | 35 | - | - | - | - | - | - |
$558 7,034 kWh |
$511 35 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,471 Cost: $7,825 |
$1,625 | 20,516 | $846 | 58 | - | - | - | - | - | - |
$1,625 20,516 kWh |
$846 58 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $3,739 Cost: $3,334 |
$2,281 | 28,722 | $2,511 | 173 | $(-1,053) | (-140) | - | - | - | - |
$2,281 28,722 kWh |
$2,511 173 kW-months/year |
$(-1,053) (-140) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $151 Cost: - |
$41 | 586 | $110 | 8 | - | - | - | - | - | - |
$41 586 kWh |
$110 8 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $8,640 Cost: $510 |
- | - | - | - | - | - | - | - | $8,640 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$8,640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $119,957 Cost: $150,000 |
- | - | - | - | - | - | $119,957 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$119,957 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $189,154 Cost: $223,047 |
$41,001 | 517,585 | $20,609 | 1,419 | $(-1,053) | (-140) | $119,957 | - | $8,640 | - | $41,001 517,585 kWh |
$20,609 1,419 kW-months/year |
$(-1,053) (-140) MMBtu |
$119,957 - $ |
$8,640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,069 Cost: $1,425 |
$558 | 7,034 | $511 | 35 | - | - | - | - | - | - | $558 7,034 kWh |
$511 35 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||