Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2002
Principal Product laminated panels for motor homes/RV's electronic and furniture industrie
NAICS n/a
SIC 3448 - Prefabricated Metal Buildings
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 120,000
Annual Production 20,000,000 Thousand Feet
Production Hrs. Annual 4,250
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $196,204 1,770,957 kWh $0.11
Electricity Demand $72,863 8,757 kW-months/year $8.32
Electricity Fees $1,440 - $ -
Natural Gas $1,534 118 MMBtu $13.00
TOTAL ENERGY COSTS $276,265
RECOMMENDED SAVINGS* $182,753 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $57,485
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes
$ kWh $ kW-months/year $ $
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$42,804
Cost:
$52,000
$35,316 318,736 $7,488 900 - - $35,316
318,736
kWh
$7,488
900
kW-months/year
-
-
$
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$4,322
Cost:
$3,700
$3,565 32,171 $757 91 - - $3,565
32,171
kWh
$757
91
kW-months/year
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$5,121
Cost:
$1,000
$3,199 28,875 $1,922 231 - - $3,199
28,875
kWh
$1,922
231
kW-months/year
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,238
Cost:
$280
$4,299 38,804 $939 113 - - $4,299
38,804
kWh
$939
113
kW-months/year
-
-
$
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$2,851
Cost:
$4,092
$2,124 19,172 $727 87 - - $2,124
19,172
kWh
$727
87
kW-months/year
-
-
$
06: 3.2176 INCREASE USE OF AUTOMATION Savings:
$122,000
Cost:
$45,000
- - - - $122,000 - -
-
kWh
-
-
kW-months/year
$122,000
-
$
07: 2.8123 PAY UTILITY BILLS ON TIME Savings:
$417
Cost:
-
- - - - $417 - -
-
kWh
-
-
kW-months/year
$417
-
$
TOTAL RECOMMENDED Savings:
$182,753
Cost:
$106,072
$48,503 437,758 $11,833 1,422 $122,417 - $48,503
437,758
kWh
$11,833
1,422
kW-months/year
$122,417
-
$
TOTAL IMPLEMENTED Savings:
$57,485
Cost:
$56,980
$46,379 418,586 $11,106 1,335 - - $46,379
418,586
kWh
$11,106
1,335
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes