IAC logo
IAC Assessment: SD0383
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0383
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2006
Principal Product aluminum forgings
NAICS 332112 - Nonferrous Forging
SIC 3463 - Nonferrous Forgings
Sales $50,000,000-$100,000,000
# of Employees 350
Plant Area (Sq.Ft.) 100,000
Annual Production 0 Units
Production Hrs. Annual 0
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $474,210 6,451,835 kWh $0.07
Electricity Demand $333,201 18,975 kW-months/year $17.56
Natural Gas $1,229,510 135,111 MMBtu $9.10
TOTAL ENERGY COSTS $2,036,921
RECOMMENDED SAVINGS* $79,353 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$33,958
Cost:
-
$25,318 344,468 $8,640 492 - - $25,318
344,468
kWh
$8,640
492
kW-months/year
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$17,420
Cost:
$260
$11,976 162,943 $5,444 310 - - $11,976
162,943
kWh
$5,444
310
kW-months/year
-
-
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$14,249
Cost:
$26,550
$14,249 193,867 - - - - $14,249
193,867
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING Savings:
$5,803
Cost:
$900
$5,803 78,957 - - - - $5,803
78,957
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,966
Cost:
$4,300
$3,966 53,972 - - - - $3,966
53,972
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,957
Cost:
$4,270
- - - - $3,957 4,350 -
-
kWh
-
-
kW-months/year
$3,957
4,350
MMBtu
TOTAL RECOMMENDED Savings:
$79,353
Cost:
$36,280
$61,312 834,207 $14,084 802 $3,957 4,350 $61,312
834,207
kWh
$14,084
802
kW-months/year
$3,957
4,350
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas