Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2012
Principal Product Reclaimed Water
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4952 - Sewerage Systems
Sales $1,000,000-$5,000,000
# of Employees 13
Plant Area (Sq.Ft.) 20,000,000
Annual Production 16,000,000 Units
Production Hrs. Annual 8,760
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,003,660 17,323,115 kWh $0.06
Electricity Fees $278,160 - $ -
TOTAL ENERGY COSTS $1,281,820
RECOMMENDED SAVINGS* $239,925 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $233,686
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$6,239
Cost:
$100
$6,239 107,761 - - $6,239
107,761
kWh
-
-
$
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$10,195
Cost:
$3,320
$10,195 176,085 - - $10,195
176,085
kWh
-
-
$
03: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS Savings:
$122,834
Cost:
$75,600
$122,834 2,121,492 - - $122,834
2,121,492
kWh
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,602
Cost:
$11,102
$8,602 148,562 - - $8,602
148,562
kWh
-
-
$
05: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$92,055
Cost:
$415,000
$164,872 2,842,620 $(-72,818) - $164,872
2,842,620
kWh
$(-72,818)
-
$
TOTAL RECOMMENDED Savings:
$239,925
Cost:
$505,122
$312,742 5,396,520 $(-72,818) - $312,742
5,396,520
kWh
$(-72,818)
-
$
TOTAL IMPLEMENTED Savings:
$233,686
Cost:
$505,022
$306,503 5,288,759 $(-72,818) - $306,503
5,288,759
kWh
$(-72,818)
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes