Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2013
Principal Product Air Conditioning Enclosures
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585 - Refrigeration And Heating Equipment
Sales $10,000,000-$50,000,000
# of Employees 166
Plant Area (Sq.Ft.) 100,000
Annual Production 5,000 Pieces
Production Hrs. Annual 4,264
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $87,257 695,374 kWh $0.13
Electricity Demand $43,039 3,324 kW-months/year $12.95
Electricity Fees $3,325 - $ -
Natural Gas $14,084 2,097 MMBtu $6.72
TOTAL ENERGY COSTS $147,705
RECOMMENDED SAVINGS* $17,092 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,768
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,304
Cost:
$1,500
$3,383 26,954 $921 71 $3,383
26,954
kWh
$921
71
kW-months/year
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,131
Cost:
$6,224
$3,248 25,881 $883 68 $3,248
25,881
kWh
$883
68
kW-months/year
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$2,625
Cost:
$1,850
$2,034 16,210 $591 46 $2,034
16,210
kWh
$591
46
kW-months/year
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$2,768
Cost:
$2,210
$2,768 22,049 - - $2,768
22,049
kWh
-
-
kW-months/year
05: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$2,233
Cost:
$5,250
$2,233 17,792 - - $2,233
17,792
kWh
-
-
kW-months/year
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$564
Cost:
$200
$564 4,497 - - $564
4,497
kWh
-
-
kW-months/year
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$467
Cost:
$200
- - $467 36 -
-
kWh
$467
36
kW-months/year
TOTAL RECOMMENDED Savings:
$17,092
Cost:
$17,434
$14,230 113,383 $2,862 221 $14,230
113,383
kWh
$2,862
221
kW-months/year
TOTAL IMPLEMENTED Savings:
$2,768
Cost:
$2,210
$2,768 22,049 - - $2,768
22,049
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand