Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2013 |
Principal Product | APET containers |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 178,000 |
Annual Production | 500,000,000 Pieces |
Production Hrs. Annual | 8,400 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,127,293 | 27,153,716 | kWh | $0.08 |
Electricity Demand | $469,705 | 53,911 | kW-months/year | $8.71 |
Natural Gas | $132,720 | 26,538 | MMBtu | $5.00 |
TOTAL ENERGY COSTS | $2,729,718 | |||
RECOMMENDED SAVINGS* | $623,463 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $82,016 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $404,689 Cost: $1,152,300 |
$612,304 | 7,819,980 | $100,820 | 11,575 | $(-241,303) | (-48,251) | $(-67,132) | - |
$612,304 7,819,980 kWh |
$100,820 11,575 kW-months/year |
$(-241,303) (-48,251) MMBtu |
$(-67,132) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $47,675 Cost: $150,500 |
$42,689 | 545,203 | $4,986 | 572 | - | - | - | - |
$42,689 545,203 kWh |
$4,986 572 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $44,050 Cost: $30,000 |
$44,050 | 562,590 | - | - | - | - | - | - |
$44,050 562,590 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $40,480 Cost: $35,200 |
$44,377 | 566,757 | $7,897 | 907 | $(-11,794) | (-2,358) | - | - |
$44,377 566,757 kWh |
$7,897 907 kW-months/year |
$(-11,794) (-2,358) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $37,276 Cost: $40,200 |
$34,230 | 437,162 | $3,046 | 350 | - | - | - | - |
$34,230 437,162 kWh |
$3,046 350 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $23,678 Cost: $87,264 |
$23,678 | 302,400 | - | - | - | - | - | - |
$23,678 302,400 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $15,779 Cost: $45,500 |
- | - | - | - | $15,779 | 3,155 | - | - |
- - kWh |
- - kW-months/year |
$15,779 3,155 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $5,576 Cost: $16,500 |
$5,166 | 65,981 | $410 | 47 | - | - | - | - |
$5,166 65,981 kWh |
$410 47 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,172 Cost: $5,250 |
$1,811 | 23,133 | $361 | 41 | - | - | - | - |
$1,811 23,133 kWh |
$361 41 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,088 Cost: $7,400 |
$2,008 | 25,651 | $80 | 9 | - | - | - | - |
$2,008 25,651 kWh |
$80 9 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $623,463 Cost: $1,570,114 |
$810,313 | 10,348,857 | $117,600 | 13,502 | $(-237,318) | (-47,454) | $(-67,132) | - | $810,313 10,348,857 kWh |
$117,600 13,502 kW-months/year |
$(-237,318) (-47,454) MMBtu |
$(-67,132) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $82,016 Cost: $88,050 |
$82,426 | 1,052,703 | $11,384 | 1,307 | $(-11,794) | (-2,358) | - | - | $82,426 1,052,703 kWh |
$11,384 1,307 kW-months/year |
$(-11,794) (-2,358) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |