Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2014 |
Principal Product | Furniture |
NAICS | 337124 - Metal Household Furniture Manufacturing |
SIC | 2514 - Metal Household Furniture |
Sales | $1,000,000-$5,000,000 |
# of Employees | 240 |
Plant Area (Sq.Ft.) | 200,645 |
Annual Production | 106,000 Pieces |
Production Hrs. Annual | 2,168 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $86,346 | 1,161,152 | kWh | $0.07 |
Electricity Demand | $88,061 | 4,622 | kW-months/year | $19.05 |
Electricity Fees | $9,797 | - | $ | - |
Natural Gas | $67,781 | 10,750 | MMBtu | $6.31 |
TOTAL ENERGY COSTS | $251,985 | |||
RECOMMENDED SAVINGS* | $36,746 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,638 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $18,026 Cost: $61,400 |
$14,092 | 189,408 | $3,934 | 207 | - | - |
$14,092 189,408 kWh |
$3,934 207 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7,108 Cost: $21,254 |
- | - | - | - | $7,108 | 1,130 |
- - kWh |
- - kW-months/year |
$7,108 1,130 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,486 Cost: $2,845 |
- | - | - | - | $5,486 | 872 |
- - kWh |
- - kW-months/year |
$5,486 872 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,633 Cost: $2,600 |
$2,633 | 35,390 | - | - | - | - |
$2,633 35,390 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,563 Cost: $3,243 |
$(-395) | (-5,306) | $(-512) | (-27) | $2,470 | 393 |
$(-395) (-5,306) kWh |
$(-512) (-27) kW-months/year |
$2,470 393 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,147 Cost: $500 |
$670 | 8,997 | $477 | 25 | - | - |
$670 8,997 kWh |
$477 25 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $783 Cost: $500 |
- | - | $783 | 50 | - | - |
- - kWh |
$783 50 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $36,746 Cost: $92,342 |
$17,000 | 228,489 | $4,682 | 254 | $15,064 | 2,395 | $17,000 228,489 kWh |
$4,682 254 kW-months/year |
$15,064 2,395 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,638 Cost: $71,088 |
$17,000 | 228,489 | $4,682 | 254 | $7,956 | 1,265 | $17,000 228,489 kWh |
$4,682 254 kW-months/year |
$7,956 1,265 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |