Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2015
Principal Product Corrugated paper boxes
NAICS 322211 - Corrugated and Solid Fiber Box Manufacturing
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales <$500,000
# of Employees 150
Plant Area (Sq.Ft.) 175,000
Annual Production 80,001 Units
Production Hrs. Annual 7,488
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $79,276 1,096,327 kWh $0.07
Electricity Demand $62,893 2,673 kW-months/year $23.53
Electricity Fees $6,290 - $ -
TOTAL ENERGY COSTS $148,459
RECOMMENDED SAVINGS* $72,365 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $66,819
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$43,186
Cost:
$113,400
$18,259 252,533 $24,927 1,059 $18,259
252,533
kWh
$24,927
1,059
kW-months/year
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$10,851
Cost:
$12,449
$10,851 150,081 - - $10,851
150,081
kWh
-
-
kW-months/year
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$9,239
Cost:
$7,006
$6,072 83,965 $3,167 135 $6,072
83,965
kWh
$3,167
135
kW-months/year
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,546
Cost:
$18,500
- - $5,546 240 -
-
kWh
$5,546
240
kW-months/year
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$2,674
Cost:
$2,420
$2,120 29,319 $554 24 $2,120
29,319
kWh
$554
24
kW-months/year
06: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$869
Cost:
$1,356
$695 9,608 $174 7 $695
9,608
kWh
$174
7
kW-months/year
TOTAL RECOMMENDED Savings:
$72,365
Cost:
$155,131
$37,997 525,506 $34,368 1,465 $37,997
525,506
kWh
$34,368
1,465
kW-months/year
TOTAL IMPLEMENTED Savings:
$66,819
Cost:
$136,631
$37,997 525,506 $28,822 1,225 $37,997
525,506
kWh
$28,822
1,225
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand