Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2015
Principal Product aerospace and naval materials
NAICS 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3429 - Hardware, Nec
Sales $50,000,000-$100,000,000
# of Employees 400
Plant Area (Sq.Ft.) 215,000
Annual Production 80,001 Pieces
Production Hrs. Annual 3,700
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $466,655 4,979,240 kWh $0.09
Electricity Demand $359,535 17,616 kW-months/year $20.41
Electricity Fees $22,457 - $ -
TOTAL ENERGY COSTS $848,647
RECOMMENDED SAVINGS* $120,645 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $120,645
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$43,686
Cost:
$162,100
$25,048 267,347 $18,638 913 - - $25,048
267,347
kWh
$18,638
913
kW-months/year
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$31,173
Cost:
$100,875
$16,550 176,615 $14,623 717 - - $16,550
176,615
kWh
$14,623
717
kW-months/year
-
-
$
03: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$25,778
Cost:
$100,200
$21,085 225,045 $4,693 230 - - $21,085
225,045
kWh
$4,693
230
kW-months/year
-
-
$
04: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT Savings:
$13,855
Cost:
$24,332
$7,555 80,630 - - $6,300 - $7,555
80,630
kWh
-
-
kW-months/year
$6,300
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,765
Cost:
$9,630
$3,765 40,178 - - - - $3,765
40,178
kWh
-
-
kW-months/year
-
-
$
06: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,826
Cost:
$2,590
$1,826 19,480 - - - - $1,826
19,480
kWh
-
-
kW-months/year
-
-
$
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$562
Cost:
$214
$562 6,001 - - - - $562
6,001
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$120,645
Cost:
$399,941
$76,391 815,296 $37,954 1,860 $6,300 - $76,391
815,296
kWh
$37,954
1,860
kW-months/year
$6,300
-
$
TOTAL IMPLEMENTED Savings:
$120,645
Cost:
$399,941
$76,391 815,296 $37,954 1,860 $6,300 - $76,391
815,296
kWh
$37,954
1,860
kW-months/year
$6,300
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees