IAC logo
IAC Assessment: SD0670
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0670
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2025
Principal Product Furniture
NAICS 337127 - Institutional Furniture Manufacturing
SIC 2599 - Furniture And Fixtures, Nec
Sales $5,000,000-$10,000,000
# of Employees 44
Plant Area (Sq.Ft.) 32,000
Annual Production 60 Pieces
Production Hrs. Annual 2,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $39,097 320,430 kWh $0.12
Electricity Demand $65,480 2,178 kW-months/year $30.06
Electricity Fees $2,576 - $ -
TOTAL ENERGY COSTS $107,153
RECOMMENDED SAVINGS* $42,778 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$30,558
Cost:
$134,423
$14,954 122,570 $15,605 519 $14,954
122,570
kWh
$15,605
519
kW-months/year
02: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL Savings:
$5,044
Cost:
$470
$(-439) (-3,600) $5,483 182 $(-439)
(-3,600)
kWh
$5,483
182
kW-months/year
03: 2.4223 INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM Savings:
$1,711
Cost:
$6,733
$1,711 14,022 - - $1,711
14,022
kWh
-
-
kW-months/year
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$161
Cost:
$932
$122 998 $40 1 $122
998
kWh
$40
1
kW-months/year
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$60
Cost:
-
$60 489 - - $60
489
kWh
-
-
kW-months/year
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,220
Cost:
$3,314
$875 7,161 $1,345 45 $875
7,161
kWh
$1,345
45
kW-months/year
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,896
Cost:
$9,455
$1,593 13,050 $303 10 $1,593
13,050
kWh
$303
10
kW-months/year
08: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$669
Cost:
$511
$669 5,480 - - $669
5,480
kWh
-
-
kW-months/year
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$459
Cost:
$1,842
$459 3,762 - - $459
3,762
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$42,778
Cost:
$157,680
$20,002 163,932 $22,776 758 $20,002
163,932
kWh
$22,776
758
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand