Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1995
Principal Product Circuit Boards
NAICS n/a
SIC 3672 - Printed Circuit Boards
Sales $10,000,000-$50,000,000
# of Employees 165
Plant Area (Sq.Ft.) 39,692
Annual Production 1,740 Thousand Feet
Production Hrs. Annual 7,488
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $511,596 5,232,415 kWh $0.10
Natural Gas $49,048 8,267 MMBtu $5.93
TOTAL ENERGY COSTS $560,644
RECOMMENDED SAVINGS* $128,899 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,573
#|Description Savings
Cost
Status Electricity Usage Natural Gas Primary Product Electricity Usage Natural Gas Primary Product
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,510
Cost:
$516
$1,510 15,533 - - - - $1,510
15,533
kWh
-
-
MMBtu
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$12,565
Cost:
$4,400
$12,565 128,664 - - - - $12,565
128,664
kWh
-
-
MMBtu
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,063
Cost:
$1,400
$3,063 31,360 - - - - $3,063
31,360
kWh
-
-
MMBtu
-
-
$
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,794
Cost:
$605
- - $1,794 302 - - -
-
kWh
$1,794
302
MMBtu
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,711
Cost:
$4,400
$3,711 38,101 - - - - $3,711
38,101
kWh
-
-
MMBtu
-
-
$
06: 2.3322 USE EXISTING DAM TO GENERATE ELECTRICITY Savings:
$59,850
Cost:
$122,000
$(-150) (-7,327) - - $60,000 - $(-150)
(-7,327)
kWh
-
-
MMBtu
$60,000
-
$
07: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$46,406
Cost:
$42,000
$65,896 674,091 $(-19,490) (-3,286) - - $65,896
674,091
kWh
$(-19,490)
(-3,286)
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$128,899
Cost:
$175,321
$86,595 880,422 $(-17,696) (-2,984) $60,000 - $86,595
880,422
kWh
$(-17,696)
(-2,984)
MMBtu
$60,000
-
$
TOTAL IMPLEMENTED Savings:
$4,573
Cost:
$1,916
$4,573 46,893 - - - - $4,573
46,893
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Primary Product Electricity Usage Natural Gas Primary Product