Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1998 |
Principal Product | Telecommunications Equipment |
NAICS | n/a |
SIC | 3661 - Telephone And Telegraph Apparatus |
Sales | $50,000,000-$100,000,000 |
# of Employees | 270 |
Plant Area (Sq.Ft.) | 105,000 |
Annual Production | 24,000 Pieces |
Production Hrs. Annual | 3,380 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $136,639 | 1,586,166 | kWh | $0.09 |
Electricity Demand | $18,141 | 4,099 | kW-months/year | $4.43 |
Natural Gas | $7,013 | 1,103 | MMBtu | $6.36 |
TOTAL ENERGY COSTS | $211,121 | |||
RECOMMENDED SAVINGS* | $47,625 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,219 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,024 Cost: - |
$1,024 | 12,016 | - | - | - | - | - | - |
$1,024 12,016 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $5,884 Cost: $280 |
$5,884 | 68,288 | - | - | - | - | - | - |
$5,884 68,288 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,527 Cost: $1,180 |
$2,226 | 25,791 | - | - | $(-699) | (-110) | - | - |
$2,226 25,791 kWh |
- - kW-months/year |
$(-699) (-110) MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $415 Cost: $329 |
$366 | 4,396 | $49 | 11 | - | - | - | - |
$366 4,396 kWh |
$49 11 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,572 Cost: $1,742 |
$2,240 | 26,084 | - | - | $(-668) | (-105) | - | - |
$2,240 26,084 kWh |
- - kW-months/year |
$(-668) (-105) MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $9,888 Cost: $13,781 |
$8,707 | 101,114 | $1,181 | 267 | - | - | - | - |
$8,707 101,114 kWh |
$1,181 267 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $258 Cost: $1,700 |
$241 | 2,931 | $17 | 3 | - | - | - | - |
$241 2,931 kWh |
$17 3 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $804 Cost: $1,792 |
$670 | 7,913 | $134 | 30 | - | - | - | - |
$670 7,913 kWh |
$134 30 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,036 Cost: $8,557 |
$2,488 | 29,015 | $548 | 124 | - | - | - | - |
$2,488 29,015 kWh |
$548 124 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $11,710 Cost: $250 |
- | - | - | - | - | - | $11,710 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$11,710 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $8,504 Cost: $250 |
- | - | - | - | - | - | $8,504 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,504 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,003 Cost: $250 |
- | - | - | - | - | - | $3,003 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,003 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $47,625 Cost: $30,111 |
$23,846 | 277,548 | $1,929 | 435 | $(-1,367) | (-215) | $23,217 | - | $23,846 277,548 kWh |
$1,929 435 kW-months/year |
$(-1,367) (-215) MMBtu |
$23,217 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,219 Cost: $2,572 |
$7,578 | 88,217 | $134 | 30 | - | - | $11,507 | - | $7,578 88,217 kWh |
$134 30 kW-months/year |
- - MMBtu |
$11,507 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |