Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1999
Principal Product Injection Molded Plastic Parts, Industrial Molds
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $1,000,000-$5,000,000
# of Employees 20
Plant Area (Sq.Ft.) 35,000
Annual Production 312 Units
Production Hrs. Annual 4,992
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $45,739 565,651 kWh $0.08
Electricity Demand $8,761 2,037 kW-months/year $4.30
Natural Gas $1,415 201 MMBtu $7.04
TOTAL ENERGY COSTS $57,344
RECOMMENDED SAVINGS* $104,769 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,306
Cost:
$2,000
$2,047 25,205 $259 61 - - $2,047
25,205
kWh
$259
61
kW-months/year
-
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$4,073
Cost:
$2,652
$3,831 47,773 $242 57 - - $3,831
47,773
kWh
$242
57
kW-months/year
-
-
$
03: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$4,245
Cost:
$7,048
$3,687 45,721 $558 131 - - $3,687
45,721
kWh
$558
131
kW-months/year
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$787
Cost:
$1,317
$787 9,672 - - - - $787
9,672
kWh
-
-
kW-months/year
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,261
Cost:
$9,625
$2,053 25,498 $208 49 - - $2,053
25,498
kWh
$208
49
kW-months/year
-
-
$
06: 4.1110 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$91,097
Cost:
$280,750
$3,344 41,325 $393 92 $87,360 - $3,344
41,325
kWh
$393
92
kW-months/year
$87,360
-
$
TOTAL RECOMMENDED Savings:
$104,769
Cost:
$303,392
$15,749 195,194 $1,660 390 $87,360 - $15,749
195,194
kWh
$1,660
390
kW-months/year
$87,360
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes