Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1999 |
Principal Product | Nutritional Suplements |
NAICS | n/a |
SIC | 2834 - Pharmaceutical Preparations |
Sales | $1,000,000-$5,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 17,000 |
Annual Production | 1,300,000 Pieces |
Production Hrs. Annual | 2,730 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $16,552 | 227,726 | kWh | $0.07 |
Electricity Demand | $4,000 | 717 | kW-months/year | $5.58 |
Natural Gas | $6,152 | 985 | MMBtu | $6.25 |
TOTAL ENERGY COSTS | $35,554 | |||
RECOMMENDED SAVINGS* | $71,514 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $36,310 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $276 Cost: $480 |
$206 | 2,931 | $70 | 70 | - | - | - | - |
$206 2,931 kWh |
$70 70 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,662 Cost: $6,782 |
$2,065 | 28,429 | $597 | 18 | - | - | - | - |
$2,065 28,429 kWh |
$597 18 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $564 Cost: $2,476 |
$564 | 7,913 | - | - | - | - | - | - |
$564 7,913 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $1,350 Cost: $150 |
- | - | - | - | $1,350 | - | - | - |
- - kWh |
- - kW-months/year |
$1,350 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $600 Cost: $150 |
- | - | - | - | $600 | - | - | - |
- - kWh |
- - kW-months/year |
$600 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $312 Cost: $150 |
- | - | - | - | $312 | - | - | - |
- - kWh |
- - kW-months/year |
$312 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $6,334 Cost: $8,650 |
- | - | - | - | $6,334 | - | - | - |
- - kWh |
- - kW-months/year |
$6,334 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $7,000 Cost: $838 |
- | - | - | - | - | - | $7,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$7,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $26,208 Cost: $33,300 |
- | - | - | - | - | - | $26,208 | - |
- - kWh |
- - kW-months/year |
- - lb |
$26,208 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $26,208 Cost: $33,300 |
- | - | - | - | - | - | $26,208 | - |
- - kWh |
- - kW-months/year |
- - lb |
$26,208 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $71,514 Cost: $86,276 |
$2,835 | 39,273 | $667 | 88 | $8,596 | - | $59,416 | - | $2,835 39,273 kWh |
$667 88 kW-months/year |
$8,596 - lb |
$59,416 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $36,310 Cost: $37,544 |
$770 | 10,844 | $70 | 70 | $2,262 | - | $33,208 | - | $770 10,844 kWh |
$70 70 kW-months/year |
$2,262 - lb |
$33,208 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes |