Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2003 |
Principal Product | Newspaper |
NAICS | 511110 - Newspaper Publishers |
SIC | 2711 - Newspapers |
Sales | $50,000,000-$100,000,000 |
# of Employees | 625 |
Plant Area (Sq.Ft.) | 156,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 3,328 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $185,845 | 5,065,104 | kWh | $0.04 |
Electricity Demand | $96,904 | 11,094 | kW-months/year | $8.73 |
Natural Gas | $22,528 | 3,608 | MMBtu | $6.24 |
TOTAL ENERGY COSTS | $319,948 | |||
RECOMMENDED SAVINGS* | $43,401 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,807 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,228 Cost: $140 |
$878 | 23,919 | $350 | 40 | - | - |
$878 23,919 kWh |
$350 40 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $9,649 Cost: $3,715 |
$5,192 | 141,513 | $4,457 | 510 | - | - |
$5,192 141,513 kWh |
$4,457 510 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $7,212 Cost: $5,250 |
$5,866 | 159,896 | $1,346 | 154 | - | - |
$5,866 159,896 kWh |
$1,346 154 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,226 Cost: $3,400 |
$2,226 | 60,650 | - | - | - | - |
$2,226 60,650 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,416 Cost: $13,464 |
$3,471 | 94,607 | $2,945 | 337 | - | - |
$3,471 94,607 kWh |
$2,945 337 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,302 Cost: $7,220 |
$1,972 | 53,761 | $1,330 | 152 | - | - |
$1,972 53,761 kWh |
$1,330 152 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $353 Cost: $796 |
$252 | 6,871 | $101 | 12 | - | - |
$252 6,871 kWh |
$101 12 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,337 Cost: $587 |
$9,295 | 253,328 | $3,042 | 348 | - | - |
$9,295 253,328 kWh |
$3,042 348 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $678 Cost: $1,749 |
- | - | $215 | 20 | $463 | - |
- - kWh |
$215 20 kW-months/year |
$463 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,401 Cost: $36,321 |
$29,152 | 794,545 | $13,786 | 1,573 | $463 | - | $29,152 794,545 kWh |
$13,786 1,573 kW-months/year |
$463 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,807 Cost: $4,336 |
$3,356 | 91,440 | $451 | 52 | - | - | $3,356 91,440 kWh |
$451 52 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |