IAC logo
IAC Assessment: SF0270
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0270
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2003
Principal Product Wines
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $50,000,000-$100,000,000
# of Employees 53
Plant Area (Sq.Ft.) 100,000
Annual Production 0 Units
Production Hrs. Annual 5,137
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $140,507 1,338,640 kWh $0.10
Electricity Demand $39,460 3,811 kW-months/year $10.35
Natural Gas $10,134 1,676 MMBtu $6.05
TOTAL ENERGY COSTS $220,990
RECOMMENDED SAVINGS* $59,233 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $18,201
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost
$ kWh $ kW-months/year $ lb $ $
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$2,671
Cost:
-
$2,671 25,446 - - - - - - $2,671
25,446
kWh
-
-
kW-months/year
-
-
lb
-
-
$
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$244
Cost:
-
$244 2,329 - - - - - - $244
2,329
kWh
-
-
kW-months/year
-
-
lb
-
-
$
03: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$9,405
Cost:
$4,145
$9,405 89,566 - - - - - - $9,405
89,566
kWh
-
-
kW-months/year
-
-
lb
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$14,226
Cost:
$9,485
$10,741 102,332 $3,485 318 - - - - $10,741
102,332
kWh
$3,485
318
kW-months/year
-
-
lb
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,081
Cost:
$830
$879 8,374 $202 20 - - - - $879
8,374
kWh
$202
20
kW-months/year
-
-
lb
-
-
$
06: 2.7145 INSTALL SKYLIGHTS Savings:
$3,975
Cost:
$10,800
$2,623 24,990 $1,352 131 - - - - $2,623
24,990
kWh
$1,352
131
kW-months/year
-
-
lb
-
-
$
07: 3.7312 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS Savings:
$3,034
Cost:
-
- - - - - - $3,034 - -
-
kWh
-
-
kW-months/year
-
-
lb
$3,034
-
$
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$9,418
Cost:
$9,500
- - - - $9,418 408 - - -
-
kWh
-
-
kW-months/year
$9,418
408
lb
-
-
$
09: 4.2120 ADOPT IN-HOUSE MATERIAL GENERATION Savings:
$15,179
Cost:
$80,393
- - - - - - $15,179 - -
-
kWh
-
-
kW-months/year
-
-
lb
$15,179
-
$
TOTAL RECOMMENDED Savings:
$59,233
Cost:
$115,153
$26,563 253,037 $5,039 469 $9,418 408 $18,213 - $26,563
253,037
kWh
$5,039
469
kW-months/year
$9,418
408
lb
$18,213
-
$
TOTAL IMPLEMENTED Savings:
$18,201
Cost:
$20,285
$13,364 127,322 $4,837 449 - - - - $13,364
127,322
kWh
$4,837
449
kW-months/year
-
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $
Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost