Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2004 |
Principal Product | Clay Tiles |
NAICS | 327120 - Clay Building Material and Refractories Manufacturing |
SIC | 3253 - Ceramic Wall And Floor Tile |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 65,750 |
Annual Production | 11,500,000 Pieces |
Production Hrs. Annual | 6,528 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $100,465 | 789,333 | kWh | $0.13 |
Electricity Demand | $8,193 | 2,077 | kW-months/year | $3.94 |
Natural Gas | $208,785 | 27,234 | MMBtu | $7.67 |
TOTAL ENERGY COSTS | $343,305 | |||
RECOMMENDED SAVINGS* | $38,806 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,116 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $850 Cost: $282 |
$806 | 6,340 | $44 | 11 | - | - | - | - | - | - |
$806 6,340 kWh |
$44 11 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $8,781 Cost: $4,375 |
- | - | - | - | $8,781 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,781 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,936 Cost: $3,085 |
$4,672 | 36,663 | $264 | 67 | - | - | - | - | - | - |
$4,672 36,663 kWh |
$264 67 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,262 Cost: $2,760 |
$1,951 | 15,339 | $311 | 79 | - | - | - | - | - | - |
$1,951 15,339 kWh |
$311 79 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,058 Cost: $2,880 |
$1,746 | 13,728 | $312 | 79 | - | - | - | - | - | - |
$1,746 13,728 kWh |
$312 79 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,715 Cost: $2,638 |
$1,620 | 12,733 | $95 | 24 | - | - | - | - | - | - |
$1,620 12,733 kWh |
$95 24 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $753 Cost: $1,520 |
- | - | - | - | - | - | $753 | 98 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$753 98 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,293 Cost: $5,681 |
$2,293 | 18,032 | - | - | - | - | - | - | - | - |
$2,293 18,032 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,017 Cost: $3,059 |
$900 | 7,077 | $117 | 30 | - | - | - | - | - | - |
$900 7,077 kWh |
$117 30 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $14,141 Cost: $36,000 |
- | - | - | - | - | - | - | - | $14,141 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$14,141 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,806 Cost: $62,280 |
$13,988 | 109,912 | $1,143 | 290 | $8,781 | - | $753 | 98 | $14,141 | - | $13,988 109,912 kWh |
$1,143 290 kW-months/year |
$8,781 - $ |
$753 98 MMBtu |
$14,141 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,116 Cost: $11,874 |
$3,326 | 26,150 | $256 | 65 | $8,781 | - | $753 | 98 | - | - | $3,326 26,150 kWh |
$256 65 kW-months/year |
$8,781 - $ |
$753 98 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |