Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2005
Principal Product Sweetened Condensed Milk, Pancake Syrup, Olive Oil Packaging
NAICS 311514 - Dry, Condensed, and Evaporated Dairy Product Manufacturing
SIC 2023 - Dry, Condensed, Evaporated Products
Sales $10,000,000-$50,000,000
# of Employees 45
Plant Area (Sq.Ft.) 70,000
Annual Production 12,500,000 Pounds
Production Hrs. Annual 4,125
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $109,306 698,160 kWh $0.16
Natural Gas $63,335 7,195 MMBtu $8.80
TOTAL ENERGY COSTS $238,341
RECOMMENDED SAVINGS* $74,679 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Other Liquid (haz) Electricity Usage Electricity Demand Natural Gas Other Liquid (haz)
$ kWh $ kW-months/year $ MMBtu $ gal
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,347
Cost:
$480
$2,347 19,208 - - - - - - $2,347
19,208
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$728
Cost:
$120
- - - - $728 83 - - -
-
kWh
-
-
kW-months/year
$728
83
MMBtu
-
-
gal
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,633
Cost:
$3,457
$3,155 25,841 $478 111 - - - - $3,155
25,841
kWh
$478
111
kW-months/year
-
-
MMBtu
-
-
gal
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$4,150
Cost:
$2,900
$3,840 (-7,966) $310 72 - - - - $3,840
(-7,966)
kWh
$310
72
kW-months/year
-
-
MMBtu
-
-
gal
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,456
Cost:
$1,635
$1,296 10,610 $160 37 - - - - $1,296
10,610
kWh
$160
37
kW-months/year
-
-
MMBtu
-
-
gal
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,570
Cost:
$1,687
- - - - $1,570 179 - - -
-
kWh
-
-
kW-months/year
$1,570
179
MMBtu
-
-
gal
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,218
Cost:
$24,484
$11,987 98,175 $1,231 286 - - - - $11,987
98,175
kWh
$1,231
286
kW-months/year
-
-
MMBtu
-
-
gal
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$6,777
Cost:
$18,995
$6,146 50,337 $631 146 - - - - $6,146
50,337
kWh
$631
146
kW-months/year
-
-
MMBtu
-
-
gal
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,603
Cost:
$14,240
$2,274 18,623 $329 76 - - - - $2,274
18,623
kWh
$329
76
kW-months/year
-
-
MMBtu
-
-
gal
10: 3.3123 USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS Savings:
$38,197
Cost:
$66,900
- - - - - - $38,197 8,409 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$38,197
8,409
gal
TOTAL RECOMMENDED Savings:
$74,679
Cost:
$134,898
$31,045 214,828 $3,139 728 $2,298 261 $38,197 8,409 $31,045
214,828
kWh
$3,139
728
kW-months/year
$2,298
261
MMBtu
$38,197
8,409
gal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ gal
Electricity Usage Electricity Demand Natural Gas Other Liquid (haz) Electricity Usage Electricity Demand Natural Gas Other Liquid (haz)