Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2008
Principal Product Bottled wine
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $10,000,000-$50,000,000
# of Employees 77
Plant Area (Sq.Ft.) 120,000
Annual Production 300,000 Units
Production Hrs. Annual 4,368
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $241,017 2,768,977 kWh $0.09
Electricity Demand $85 7,499 kW-months/year $0.01
Electricity Fees $11,841 - $ -
Natural Gas $64,484 5,854 MMBtu $11.02
TOTAL ENERGY COSTS $317,427
RECOMMENDED SAVINGS* $168,879 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $99,551
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$9,294
Cost:
$2,185
$6,479 72,592 $2,815 222 - - $6,479
72,592
kWh
$2,815
222
kW-months/year
-
-
MMBtu
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,063
Cost:
$1,355
$2,063 23,115 - - - - $2,063
23,115
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,458
Cost:
$2,016
$1,105 12,378 $1,353 107 - - $1,105
12,378
kWh
$1,353
107
kW-months/year
-
-
MMBtu
04: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$45,262
Cost:
$60,000
$33,122 354,757 $12,140 1,003 - - $33,122
354,757
kWh
$12,140
1,003
kW-months/year
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,324
Cost:
$2,426
$1,324 14,838 - - - - $1,324
14,838
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$9,259
Cost:
$18,610
- - - - $9,259 841 -
-
kWh
-
-
kW-months/year
$9,259
841
MMBtu
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$853
Cost:
$1,675
$853 9,561 - - - - $853
9,561
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$89,877
Cost:
$118,644
$75,000 840,336 $14,877 1,173 - - $75,000
840,336
kWh
$14,877
1,173
kW-months/year
-
-
MMBtu
09: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$4,960
Cost:
$24,943
$3,946 44,217 $1,014 80 - - $3,946
44,217
kWh
$1,014
80
kW-months/year
-
-
MMBtu
10: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,273
Cost:
$11,479
$542 6,079 - - $731 66 $542
6,079
kWh
-
-
kW-months/year
$731
66
MMBtu
11: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,256
Cost:
$22,235
$2,256 25,276 - - - - $2,256
25,276
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$168,879
Cost:
$265,568
$126,690 1,403,149 $32,199 2,585 $9,990 907 $126,690
1,403,149
kWh
$32,199
2,585
kW-months/year
$9,990
907
MMBtu
TOTAL IMPLEMENTED Savings:
$99,551
Cost:
$167,838
$82,307 922,207 $17,244 1,360 - - $82,307
922,207
kWh
$17,244
1,360
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas