Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2008
Principal Product fiber drums
NAICS 322219 - Other Paperboard Container Manufacturing
SIC 2655 - Fiber Cans, Drums & Similar Products
Sales $10,000,000-$50,000,000
# of Employees 69
Plant Area (Sq.Ft.) 128,000
Annual Production 1,218,097 Pieces
Production Hrs. Annual 3,990
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $176,644 1,095,900 kWh $0.16
Electricity Fees $315 - $ -
Natural Gas $40,929 3,650 MMBtu $11.21
TOTAL ENERGY COSTS $217,888
RECOMMENDED SAVINGS* $121,067 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $25,007
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$15,195
Cost:
-
$15,195 85,189 $15,195
85,189
kWh
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,238
Cost:
$786
$1,238 6,943 $1,238
6,943
kWh
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$666
Cost:
$584
$666 3,734 $666
3,734
kWh
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,838
Cost:
$2,773
$2,838 15,908 $2,838
15,908
kWh
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$146
Cost:
$200
$146 821 $146
821
kWh
06: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,435
Cost:
$2,319
$1,435 6,971 $1,435
6,971
kWh
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$781
Cost:
$1,851
$781 4,379 $781
4,379
kWh
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$9,812
Cost:
$56,073
$9,812 55,012 $9,812
55,012
kWh
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$88,956
Cost:
$1,020,250
$88,956 498,717 $88,956
498,717
kWh
TOTAL RECOMMENDED Savings:
$121,067
Cost:
$1,084,836
$121,067 677,674 $121,067
677,674
kWh
TOTAL IMPLEMENTED Savings:
$25,007
Cost:
$56,073
$25,007 140,201 $25,007
140,201
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage